An exploratory investigation of dual‐domain denoising network for field‐free‐line magnetic particle imaging
Medical Physics · 2026-04 · 53 (4)
DOI: 10.1002/mp.70437 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, online erschienen am 12.04.2026. Verfasst von Xiangjun Wu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Interdisciplinary Institute for Medical Engineering, Fuzhou University, Fuzhou, China. Hauptthemen laut MEDLINE: Signal-To-Noise Ratio, Magnetic Particle Imaging, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 51 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Background
Magnetic particle imaging (MPI) is a functional imaging modality that enables highly sensitive tracking of magnetic nanoparticles. Field‐free‐line (FFL) MPI provides higher signal‐to‐noise ratio (SNR) than field‐free‐point MPI, however, noise in the sinogram domain and its propagation during reconstruction can introduce artifacts that degrade image quality.
Purpose
This study aims to develop a dual‐domain denoising framework to improve SNR in both the sinogram and image domains for FFL‐MPI tomographic reconstruction.
Methods
We propose DudoMTD, a dual‐domain cascaded network consisting of two components: (1) a Sinogram Denoising Transformer (SDT) integrates convolutional layers with a Vision Transformer to capture both local and long‐range angular dependencies in the sinogram domain; and (2) an edge guiding autoencoder (EGA) operates in the image domain using convolutional filtering and an adaptive Canny operator to preserve structural boundaries. Simulated sinograms were generated using a standard FFL‐MPI forward model based on the Langevin magnetization equation and system matrix formulation. The dataset consisted of 13 039 simulated images, with 80% used for training and validation and 20% for testing. In addition, FFL‐MPI phantom imaging data were used to evaluate the model under realistic measurement noise. Performance was compared with three benchmarks methods—DuDoNet, RED‐CNN, and DnCNN—using peak signal‐to‐noise ratio (PSNR), structural similarity (SSIM), and root mean square error (RMSE). Statistical significance was assessed using the Wilcoxon signed‐rank test, with Benjamini–Hochberg correction for multiple comparisons. Effect sizes (Cohen's d ) were reported to quantify the magnitude of improvements.
Results
Across four noise conditions (fixed SNRs of 15, 20, 30 dB; 30 dB with additional Poisson noise), DudoMTD showed statistically significant improvements ( p < 0.05) over all benchmark methods, with medium‐to‐large effect sizes. Specifically, the PSNR gains corresponded to Cohen's d values ranging from 0.378 to 1.311, while SSIM improvements yielded d values of 0.323–1.305. Performance gains were pronounced in the 20 dB, 30 dB, and 30 dB + Poisson noise scenarios, where DudoMTD exceeded competing methods by 3%–10% in SSIM and demonstrated consistently superior structural preservation. In phantom experiments acquired on an in‐house FFL‐MPI system, DudoMTD achieved the highest average SNR (13.809) and effectively suppressed measured noise.
Conclusion
DudoMTD mitigates dual‐domain noise in FFL‐MPI and improves tomographic image quality across diverse noise conditions. These improvements may facilitate downstream quantitative MPI applications, particularly in low‐dose imaging scenarios.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Interdisciplinary Institute for Medical Engineering, Fuzhou University, Fuzhou, China.
- School of Engineering Medicine & Key Laboratory of Big Data-Based Precision Medicine (Ministry of Industry and Information Technology), Beihang University, Beijing, China.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Wu, X., Xiong, F., An, Y., Tian, J., & Jiang, J. (2026). An exploratory investigation of dual‐domain denoising network for field‐free‐line magnetic particle imaging. Medical Physics, 53(4). https://doi.org/10.1002/mp.70437
Vancouver
Wu X, Xiong F, An Y, Tian J, Jiang J. An exploratory investigation of dual‐domain denoising network for field‐free‐line magnetic particle imaging. Medical Physics. 2026;53(4). doi:10.1002/mp.70437
BibTeX
@article{Wu2026,
author = {Wu, Xiangjun and Xiong, Fei and An, Yu and Tian, Jie and Jiang, Jingying},
title = {An exploratory investigation of dual‐domain denoising network for field‐free‐line magnetic particle imaging},
journal = {Medical Physics},
year = {2026},
volume = {53},
number = {4},
doi = {10.1002/mp.70437}
}