Anatomical feature‐guided semi‐supervised recognition of the vertebrobasilar artery for microvascular decompression
Medical Physics · 2026-04 · 53 (4)
DOI: 10.1002/mp.70352 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, online erschienen am 25.03.2026. Verfasst von Jiawei Zhang und 9 weiteren Autor:innen. Beteiligte Einrichtung: College of Information Engineering, Zhejiang University of Technology, Hangzhou, China. Hauptthemen laut MEDLINE: Microvascular Decompression Surgery, Image Processing, Computer-Assisted, Vertebral Artery, Basilar Artery. Die Arbeit nennt 32 Literaturangaben. Gefördert von: China Postdoctoral Science Foundation, Funds of the Natural Science Foundation of Hangzhou, National Natural Science Foundation of China.
Abstract (Originalsprache)
Background
Microvascular decompression (MVD) surgery is a surgical procedure commonly used in the treatment of trigeminal neuralgia, which is based on the principle of relieving compression of the responsible blood vessels. Accurate segmentation of the vertebrobasilar artery can provide physicians with more intuitive spatial location relationships, effectively improving the success rate of MVD. In recent years, various learning‐based methods have been widely used for artery segmentation. However, accurately segment the vertebrobasilar artery in complex skull base structures with little labeling data remains a challenge.
Purpose
This study seeks to identify the vessel responsible for MVD using an anatomical feature‐guided semi‐supervised automated identification approach in clinical data.
Methods
We proposed a multiscale uncertainty cross‐pseudo‐labeling network with a residual adaptive attention module. Predictions at different scales are generated through multiple decoder levels, emphasizing the reliable part of the prediction and ignoring the regions with low confidence, so that the prediction results at different scales are consistent. Meanwhile, we designed a module called Res‐AdaptiveAttention, which enables the utilization of prior knowledge related to the vertebrobasilar artery.
Results
Experiments indicated that our method could maintain the overall structure of the vertebrobasilar artery with minimal annotation labels, outperforming current semi‐supervised methods across various metrics. In terms of the dataset, this paper divided the data into a training set, validation set, and test set, with the number of cases being 58 for the training set, eight for the validation set, and 13 for the test set. Additionally, through the evaluation of clinical data, it can accurately display the lesion location, providing significant clinical application value.
Conclusions
Our method can accurately segment the vertebrobasilar artery in clinical data, and provide visual anatomical references for its positional relationship with the trigeminal nerve. This work lays a foundation for MVD preoperative planning, while further research will focus on quantifying the positional relationship between the segmented artery and trigeminal nerve at multiple anatomical locations to enhance clinical applicability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Information Engineering, Zhejiang University of Technology, Hangzhou, China.
- Academy for Advanced Interdisciplinary Science and Technology, Zhejiang University of Technology, Hangzhou, China.
- Department of Neurosurgery, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, China.
- Department of Radiology, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, China.
Förderung
- China Postdoctoral Science Foundation
- Funds of the Natural Science Foundation of Hangzhou
- National Natural Science Foundation of China
- High-level Talents in Zhejiang Province
- Natural Science Foundation of Zhejiang Province
- Postdoctoral Research Foundation of China
Zitieren
APA
Zhang, J., Xie, L., Huang, J., Xing, Z., Li, Y., Wen, C., Zhuge, Q., Pan, Y., Zeng, Q., & Feng, Y. (2026). Anatomical feature‐guided semi‐supervised recognition of the vertebrobasilar artery for microvascular decompression. Medical Physics, 53(4). https://doi.org/10.1002/mp.70352
Vancouver
Zhang J, Xie L, Huang J, Xing Z, Li Y, Wen C, et al. Anatomical feature‐guided semi‐supervised recognition of the vertebrobasilar artery for microvascular decompression. Medical Physics. 2026;53(4). doi:10.1002/mp.70352
BibTeX
@article{Zhang2026,
author = {Zhang, Jiawei and Xie, Lei and Huang, Jiahao and Xing, Zhenqiu and Li, Yongqiang and Wen, Caiyun and Zhuge, Qichuan and Pan, Yiang and Zeng, Qingrun and Feng, Yuanjing},
title = {Anatomical feature‐guided semi‐supervised recognition of the vertebrobasilar artery for microvascular decompression},
journal = {Medical Physics},
year = {2026},
volume = {53},
number = {4},
doi = {10.1002/mp.70352}
}
EUVIMED