Prior‐guided automatic delineation of post‐radiotherapy gross tumor volume for esophageal cancer
Medical Physics · 2025
DOI: 10.1002/mp.70005 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Medical Physics, 2025. Verfasst von Hongfei Sun und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Xijing Hospital, Fourth Military Medical University, Xi'an, China. Hauptthemen laut MEDLINE: Esophageal Neoplasms, Tumor Burden, Radiotherapy, Image-Guided. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Background
Integrating post‐radiotherapy (RT) CT into longitudinal esophageal cancer response models substantially improves predictive accuracy. However, manual delineation of gross tumor volume (GTV) on post‐RT CT is both labor‐intensive and time‐consuming.
Purpose
We propose a novel deep learning–based framework that integrates medical physics priors—pre‐RT GTV contours and radiotherapy dose distributions—to automatically delineate post‐RT GTV.
Methods
A multicenter retrospective cohort of 294 EC patients (225 training, 45 internal validation, 24 external validation) was assembled. Pre‐RT CT scans, GTV contours, and dose map were co‐registered and cropped to 256 × 256. We implemented an nnU‐Net v2 backbone, incorporating high dose region and pre‐RT GTV priors via element‐wise multiplication and element‐wise addition to guide feature extraction. Performance was evaluated using anatomical (Dice, IoU, HD95, ASSD, Precision, Recall) and radiomics analyses (ICC, Pearson correlation, LASSO‐Cox, C‐index) across internal and external cohorts.
Results
In cross‐validation, the optimal fold achieved DSC = 0.7809 ± 0.1310, IoU = 0.6486 ± 0.1507, HD95 = 3.6321 ± 2.0942, and ASSD = 1.9673 ± 1.0352 ( p < 0.0167 vs. state‐of‐the‐art models). Ablation studies demonstrated that combining two types of medical physics priors outperformed single‐prior or no‐prior models (internal: DSC = 0.7723 ± 0.1290; external: DSC = 0.7545 ± 0.1058). Radiomic features extracted from automated contours exhibited high reproducibility (78.6% with ICC > 0.75) and strong concordance with manual features ( R > 0.8), yielding comparable prognostic performance (C‐index Δ nonsignificant).
Conclusion
By embedding medical physics priors into a self‐configuring nnU‐Net v2, our method achieves accurate and robust automated delineation of post‐ RT GTV in EC across multiple centers. This approach has potential to facilitate the construction of treatment response prediction models.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Xijing Hospital, Fourth Military Medical University, Xi'an, China.
- Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China.
- Department of Radiation Oncology, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Chengdu, China.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Sun, H., An, Z., Huang, W., Wang, Q., Liu, Y., Shi, Z., Li, J., Meng, F., Gong, J., & Zhao, L. (2025). Prior‐guided automatic delineation of post‐radiotherapy gross tumor volume for esophageal cancer. Medical Physics. https://doi.org/10.1002/mp.70005
Vancouver
Sun H, An Z, Huang W, Wang Q, Liu Y, Shi Z, et al. Prior‐guided automatic delineation of post‐radiotherapy gross tumor volume for esophageal cancer. Medical Physics. 2025. doi:10.1002/mp.70005
BibTeX
@article{Sun2025,
author = {Sun, Hongfei and An, Ziqi and Huang, Wei and Wang, Qifeng and Liu, Yufen and Shi, Zihan and Li, Jie and Meng, Fan and Gong, Jie and Zhao, Lina},
title = {Prior‐guided automatic delineation of post‐radiotherapy gross tumor volume for esophageal cancer},
journal = {Medical Physics},
year = {2025},
doi = {10.1002/mp.70005}
}
EUVIMED