Fachartikel in der Zeitschrift Medical Physics, online erschienen am 25.09.2025. Verfasst von Dongjing Shan und 4 weiteren Autor:innen. Beteiligte Einrichtung: The Affiliated Hospital of Southwest Medical University, Luzhou, China. Hauptthemen laut MEDLINE: Radiography, Thoracic, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: Affiliated Hospital of Southwest Medical University.
Abstract (Originalsprache)
Background
Accurate classification of high‐resolution chest x‐ray (CXR) images is critical for diagnosing lung conditions such as pneumonia and identifying small lesion targets, which demands precise feature extraction from multi‐scale anatomical structures. Traditional deep learning models face challenges in balancing local detail retention and global context modeling, particularly with limited labeled data and high computational costs for high‐resolution inputs.
Purpose
This study introduces a multi‐scale nested graph transformer (MNGT) to address these challenges, aiming to enhance classification accuracy for high‐resolution CXR images while improving computational efficiency and generalization in data‐constrained scenarios.
Methods
(1) Multi‐scale nested architecture: High‐resolution CXR images are segmented into hierarchical squares: first divided into large blocks, then further subdivided into smaller patches. A graph Transformer with variable attention scope processes these patches to capture local‐to‐global features, preserving fine details of small lesions (e.g., nodule contours) while modeling long‐range dependencies (e.g., lung texture patterns); (2) Cross‐Attention Fusion: Features from high‐resolution and downscaled low‐resolution images are fused using a cross‐attention‐based graph Transformer, enabling semantic interaction between scales and enhancing lesion discriminability; (3) Graph Pooling for Efficiency: Graph pooling aggregates patches into semantic regions, reducing token count and computational complexity (e.g., from 2401 to 196 tokens) while maintaining structural integrity; (4) Inductive Bias Integration: By incorporating graph convolution and adaptive receptive field adjustments, the model mitigates overfitting in small datasets, leveraging spatial prior knowledge to improve generalization.
Results
Through extensive experiments on three types of high‐resolution CXR images, we demonstrate the superiority of our architecture, surpassing other models in terms of both accuracy and F1‐score. Furthermore, our ablation study highlights the efficiency of our designed architecture. The code including comparative models are publicly available on the Website: GitHub/MNGT .
Conclusions
MNGT provides an efficient and robust solution for high‐resolution CXR classification, combining local detail preservation, global context modeling, and inductive bias to excel in accuracy and generalization. The framework addresses the computational bottleneck of high‐resolution medical imaging and offers a viable pathway for clinical deployment in computer‐aided diagnosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The Affiliated Hospital of Southwest Medical University, Luzhou, China.
- State Key Laboratory for Novel Software Technology, Nanjing University, Nanjing, China.
- State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China.
- School of Medical Information and Engineering, Southwest Medical University, Luzhou, China.
- Institute of Tibetan Medicine, Xizang University of Tibetan Medicine, Lhasa, China.
Förderung
- Affiliated Hospital of Southwest Medical University
Zitieren
APA
Shan, D., Yang, M., Huang, L., Panduo, D., & Qu, B. (2025). Multi‐scale nested graph transformer with graph operations: Advancing high‐resolution chest x‐ray classification. Medical Physics, 52(10). https://doi.org/10.1002/mp.70003
Vancouver
Shan D, Yang M, Huang L, Panduo D, Qu B. Multi‐scale nested graph transformer with graph operations: Advancing high‐resolution chest x‐ray classification. Medical Physics. 2025;52(10). doi:10.1002/mp.70003
BibTeX
@article{Shan2025,
author = {Shan, Dongjing and Yang, Mengchu and Huang, Lu and Panduo, Dawa and Qu, Biao},
title = {Multi‐scale nested graph transformer with graph operations: Advancing high‐resolution chest x‐ray classification},
journal = {Medical Physics},
year = {2025},
volume = {52},
number = {10},
doi = {10.1002/mp.70003}
}
EUVIMED