EUVIMEDEUVIMED entdecken
Open Access

Development of anatomically variable digital Wistar rat phantoms for small animal imaging research

Hannah E Segars, Rohan Nadkarni, Cristian T Badea, Alexandra Badea, Bennett Chin, G Allan Johnson, Jason Payne, Ehsan Samei, W Paul Segars

Medical Physics · 2025-08 · 52 (8)

DOI: 10.1002/mp.18057 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, online erschienen am 13.08.2025. Verfasst von Hannah E Segars und 8 weiteren Autor:innen. Beteiligte Einrichtung: Center for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, Nort…. Hauptthemen laut MEDLINE: Phantoms, Imaging. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIH HHS, NIA NIH HHS, NIBIB NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Digital phantoms are valuable tools for evaluating small animal imaging systems. They can help optimize imaging parameters before live studies, supporting efforts to reduce animal use and refine experimental protocols. Wistar rats are widely used in preclinical imaging research due to their well‐characterized biology and relevance to human disease.

Purpose

This study develops a series of anatomically variable digital Wistar rat phantoms to support small animal imaging research.

Methods

We constructed 10 computational Wistar rat phantoms (six males, four females) with weights ranging from 188 to 474 g using high‐resolution (200 µm) co‐registered micro‐CT and MRI data to generate detailed 3D anatomical models. The segmented organs and bones, including 35 distinct anatomical tissues, were fitted with smooth polygon mesh surfaces, ensuring flexibility for modeling motion, anatomical variation, and seamless voxelization at any resolution. To demonstrate the utility of the phantoms, we conducted a photon‐counting CT (PCCT) simulation using a 279 g female model. The phantom was voxelized into material maps representing soft tissue, iodine contrast, and bone. Simulated PCCT projections were reconstructed using both analytical and iterative methods to compare image quality and accuracy of material decomposition.

Results

Measured body sizes and organ masses confirm that the computational phantoms capture inter‐subject anatomical variation. Iterative reconstruction outperformed analytical reconstruction in the PCCT simulation, reducing noise and improving material decomposition accuracy. Root mean square error (RMSE) across the water, iodine, and calcium maps decreased from 0.17 g/mL, 2.07 mg/mL, and 11.49 mg/mL to 0.02, 0.21, and 1.98, respectively.

Conclusions

The resulting anatomically variable digital phantoms will provide a valuable resource for preclinical imaging research, enabling the evaluation of imaging systems, optimization of imaging protocols, and validation of reconstruction algorithms across a representative range of anatomies. The demonstrated PCCT study highlights the potential of these phantoms for advancing virtual pre‐clinical imaging trials.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingAnimalsRatsRats, WistarFemaleMaleX-Ray MicrotomographyMagnetic Resonance ImagingImage Processing, Computer-Assisted

Stichwörter der Autor:innen

computed tomographycomputer phantommedical imaging simulationphoton‐counting CTsmall animal imaging

Autor:innen und Institutionen

  • Center for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina, USA.
  • Quantitative Imaging and Analysis Lab, Department of Radiology, Duke University Medical Center, Durham, North Carolina, USA.
  • Department of Radiology-Nuclear Medicine, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA.
  • Duke Center for In Vivo Microscopy, Duke University, Durham, North Carolina, USA.
  • Radio Frequency Bioeffects Branch, JBSA Fort Sam Houston, San Antonio, Texas, USA.

Förderung

  • NIH HHS
  • NIA NIH HHS
  • NIBIB NIH HHS
  • NCI NIH HHS
  • National Institutes of Health

Zitieren

APA

Segars, H. E., Nadkarni, R., Badea, C. T., Badea, A., Chin, B., Johnson, G. A., Payne, J., Samei, E., & Segars, W. P. (2025). Development of anatomically variable digital Wistar rat phantoms for small animal imaging research. Medical Physics, 52(8). https://doi.org/10.1002/mp.18057

Vancouver

Segars HE, Nadkarni R, Badea CT, Badea A, Chin B, Johnson GA, et al. Development of anatomically variable digital Wistar rat phantoms for small animal imaging research. Medical Physics. 2025;52(8). doi:10.1002/mp.18057

BibTeX
@article{Segars2025,
  author = {Segars, Hannah E and Nadkarni, Rohan and Badea, Cristian T and Badea, Alexandra and Chin, Bennett and Johnson, G Allan and Payne, Jason and Samei, Ehsan and Segars, W Paul},
  title = {Development of anatomically variable digital Wistar rat phantoms for small animal imaging research},
  journal = {Medical Physics},
  year = {2025},
  volume = {52},
  number = {8},
  doi = {10.1002/mp.18057}
}
Kostenlos starten →