Predicting sacral insufficiency fractures in carbon ion therapy for sacral chordoma: The role of RBE‐weighted dose, dose‐averaged LET, and volume
Medical Physics · 2025-08 · 52 (8)
DOI: 10.1002/mp.18045 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, online erschienen am 13.08.2025. Verfasst von Silvia Molinelli und 10 weiteren Autor:innen. Beteiligte Einrichtung: Radiation Oncology Unit, CNAO National Center for Oncological Hadrontherapy, Pavia, Italy. Hauptthemen laut MEDLINE: Sacrum, Heavy Ion Radiotherapy, Chordoma, Radiation Dosage. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 24 Literaturangaben.
Abstract (Originalsprache)
Background
A previous retrospective analysis on clinical outcomes of carbon‐ion radiation therapy (CIRT) for large sacral chordoma patients highlighted the potential correlation between tumor relapse and suboptimal dose‐averaged LET (LET d ) distribution, triggering the need for implementation of LET d ‐based objectives in clinical practice.
Purpose
To investigate the synergetic role played by RBE‐weighted dose (D RBE ) and LET d in the occurrence of sacral insufficiency fractures (SIF) after CIRT for sacral chordoma patients, in view of the clinical application of LET d ‐based plan optimization.
Methods
We retrospectively analyzed 73 patients, consecutively treated between 2013 and 2021, with radical CIRT and classified the occurrence of SIF during follow‐up. The prescribed dose ranged from 70.4 to 76.8 Gy (RBE), in 16 fractions, according to the local‐effect‐model I (LEM). The median follow‐up was 36 months (range 2–115). For all patients, sacral bone was contoured to calculate the corresponding D RBE ‐ LET d ‐ volume histogram (DLVH) with two RBE models. Logistic regression was used to investigate the relationship between median DLVH points of sacral bone and the likelihood of developing SIF. For patients reporting SIF at follow‐up, the fracture was contoured on the corresponding MRI sequence for a loco‐regional analysis.
Results
SIF was diagnosed in 50% of the patients, occurring after a median follow‐up of 23 months (range 2–115). The volume of sacral bone receiving a D LEM higher than 69.8 Gy(RBE) and an LET d higher than 39.7 keV/µm was significantly higher in the fractured cohort (19.5 vs. 3.6 cc) and influenced the probability of toxicity over time (AUC 0.76). The majority of the fractures (63%) were located in the high‐risk target volume.
Conclusion
Exposure of sacral bone to high‐dose radiation with LET d values of the order of 40 keV/µm emerged as a significant predictor of SIF development. Further validation on larger patient cohorts is warranted to refine individual risk stratification and to inform safer LET d ‐based treatment planning.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Radiation Oncology Unit, CNAO National Center for Oncological Hadrontherapy, Pavia, Italy.
- Department of Clinical, Surgical, Diagnostic, and Pediatric Sciences, University of Pavia, Pavia, Italy.
Zitieren
APA
Molinelli, S., Bagnalasta, M., Magro, G., Rotondi, M., Russo, S., Chalaszczyk, A., Ferrari, E., Imparato, S., Ciocca, M., Orlandi, E., & Fiore, M. R. (2025). Predicting sacral insufficiency fractures in carbon ion therapy for sacral chordoma: The role of RBE‐weighted dose, dose‐averaged LET, and volume. Medical Physics, 52(8). https://doi.org/10.1002/mp.18045
Vancouver
Molinelli S, Bagnalasta M, Magro G, Rotondi M, Russo S, Chalaszczyk A, et al. Predicting sacral insufficiency fractures in carbon ion therapy for sacral chordoma: The role of RBE‐weighted dose, dose‐averaged LET, and volume. Medical Physics. 2025;52(8). doi:10.1002/mp.18045
BibTeX
@article{Molinelli2025,
author = {Molinelli, Silvia and Bagnalasta, Matteo and Magro, Giuseppe and Rotondi, Marco and Russo, Stefania and Chalaszczyk, Agnieszka and Ferrari, Elettra and Imparato, Sara and Ciocca, Mario and Orlandi, Ester and Fiore, Maria Rosaria},
title = {Predicting sacral insufficiency fractures in carbon ion therapy for sacral chordoma: The role of RBE‐weighted dose, dose‐averaged LET, and volume},
journal = {Medical Physics},
year = {2025},
volume = {52},
number = {8},
doi = {10.1002/mp.18045}
}
EUVIMED