Vergleichsstudie in der Zeitschrift Medical Physics, 2025. Verfasst von Sandro Donato und 19 weiteren Autor:innen. Beteiligte Einrichtung: Department of, Mathematics and Computer Science, University of Calabria, Rende, Cosenza, Italy. Hauptthemen laut MEDLINE: Synchrotrons, Algorithms, Tomography, X-Ray Computed, Breast. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Health and Medical Research Council, Australia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Phase‐contrast breast CT imaging holds promise for improved diagnostic accuracy, but an optimal reconstruction algorithm must balance objective image quality metrics with subjective radiologist preferences.

Purpose

This study systematically compares three reconstruction algorithms—filtered back projection (FBP), unified tomographic reconstruction (UTR), and customized simultaneous algebraic reconstruction technique (cSART)—to identify the most suitable approach for phase‐contrast breast CT imaging.

Methods

Fresh mastectomy samples were scanned at the Australian synchrotron using monochromatic 32 keV X‐rays, a mean glandular dose of 2 mGy, flat‐panel detectors with 0.1 mm pixels, and 6‐m distance between the rotation stage and the detector. Paganin's phase retrieval method was used in conjunction with all three CT reconstruction algorithms. Objective metrics, including spatial resolution, contrast, signal‐to‐noise, and contrast‐to‐noise, were evaluated alongside subjective assessments by seven experienced radiologists. Ratings included perceptible contrast, sharpness, noise, calcification visibility, and overall quality. Results cSART excelled in objective metrics, outperforming UTR and FBP. However, subjective evaluations favored FBP due to its higher image contrast, revealing a discrepancy between objective and subjective assessments.

Conclusions

The findings highlight the contrast‐focused nature of radiologists’ subjective assessments and the potential of cSART for delivering superior objective image quality. These insights inform the development of hybrid evaluation tools and guide clinical translation for future live patient imaging studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SynchrotronsAlgorithmsTomography, X-Ray ComputedBreastRadiation DosageImage Processing, Computer-AssistedHumansFemaleMammographySignal-To-Noise Ratio

Stichwörter der Autor:innen

breast CTreconstruction algorithmssynchrotron radiation

Autor:innen und Institutionen

  • Department of, Mathematics and Computer Science, University of Calabria, Rende, Cosenza, Italy.
  • Department of Physics and STAR-Lab, University of Calabria, Rende, Cosenza, Italy.
  • Division of Frascati, INFN-Laboratori Nazionali di Frascati, Frascati (RM), Italia, Italy.
  • Department of Physics, University of Milano-Bicocca, Milano, Italy.
  • Department of Physics, University of Trieste, Trieste (TS), Italy.
  • Division of Trieste, INFN, Trieste (TS), Italy.

Förderung

  • National Health and Medical Research Council, Australia

Zitieren

APA

Donato, S., Caputo, S., Brombal, L., Golosio, B., Longo, R., Tromba, G., Agostino, R. G., Greco, G., Arhatari, B., Hall, C., Maksimenko, A., Hausermann, D., Lockie, D., Fox, J., Kumar, B., Lewis, S., Brennan, P. C., Quiney, H. M., Taba, S. T., & Gureyev, T. E. (2025). Comparison of three reconstruction algorithms for low‐dose phase‐contrast computed tomography of the breast with synchrotron radiation. Medical Physics. https://doi.org/10.1002/mp.17950

Vancouver

Donato S, Caputo S, Brombal L, Golosio B, Longo R, Tromba G, et al. Comparison of three reconstruction algorithms for low‐dose phase‐contrast computed tomography of the breast with synchrotron radiation. Medical Physics. 2025. doi:10.1002/mp.17950

BibTeX
@article{Donato2025,
  author = {Donato, Sandro and Caputo, Simone and Brombal, Luca and Golosio, Bruno and Longo, Renata and Tromba, Giuliana and Agostino, Raffaele G and Greco, Gianluigi and Arhatari, Benedicta and Hall, Chris and Maksimenko, Anton and Hausermann, Daniel and Lockie, Darren and Fox, Jane and Kumar, Beena and Lewis, Sarah and Brennan, Patrick C and Quiney, Harry M and Taba, Seyedamir T and Gureyev, Timur E},
  title = {Comparison of three reconstruction algorithms for low‐dose phase‐contrast computed tomography of the breast with synchrotron radiation},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.17950}
}
Kostenlos starten →