‘Dirty dose’‐based proton variable RBE models ‐ performance assessment on in vitro data
Medical Physics · 2025
DOI: 10.1002/mp.17519 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, 2025. Verfasst von Fredrik Kalholm und 2 weiteren Autor:innen. Beteiligte Einrichtung: Medical Radiation Physics, Department of Physics, Stockholm University, Stockholm, Sweden. Hauptthemen laut MEDLINE: Relative Biological Effectiveness, Proton Therapy, Radiation Dosage, Models, Biological. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
In clinical proton radiotherapy, a constant relative biological effectiveness (RBE) of 1.1 is typically applied. Due to abundant evidence of variable RBE effects from in vitro data, multiple variable RBE models have been suggested, typically by describing the and parameters in the linear quadratic (LQ) model as a function of dose averaged linear energy transfer ().
Purpose
This work introduces a new variable RBE model based on the dirty dose concept, where dose deposited in voxels with a corresponding LET exceeding a specific threshold is considered “dirty” in the sense that it has a biological effect above the one predicted by a constant RBE of 1.1. As only one LET level, corresponding to a specific energy for a given particle in a given medium, needs to be monitored, this offers several advantages, such as simplified calculations by removing the need for intricate end of range LET calculations and averaging procedures, as well as opening up for more efficient experimental assessment of the cell specific model parameters.
Methods
Previously published in vitro data were utilized, where surviving fraction (SF), dose and were reported for a pristine proton beam with varying physical PMMA thicknesses placed upstream of the cells. The setup was re‐simulated to extract dirty dose metrics for the corresponding reported ‐values. Models were created by setting the parameter of the LQ model as a function of the fraction of dirty dose and subsequently benchmarked against models based on other radiation quality metrics by comparing the root‐mean‐square‐error (RMSE) of the predicted and actual cell surviving fraction.
Results
Variable RBE models based on dirty dose perform on par with conventional radiation quality metrics with a RMSE of 0.38 for a dirty dose‐based model with a threshold of 7 , compared to 0.42 and 0.36 for a ‐based and ‐based model, respectively. Higher chosen LET thresholds typically performed better and lower performed worse.
Conclusion
The results indicate that models based on dirty dose metrics perform equally well as conventional radiation quality metrics. Due to the simplified calculations involved and the potential for more efficient measurement techniques for data generation, dirty dose‐based models might be the most conservative and practical approach for creating future proton variable RBE models.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Medical Radiation Physics, Department of Physics, Stockholm University, Stockholm, Sweden.
- Department of Oncology and Pathology, Medical Radiation Physics, Karolinska Institutet, Stockholm, Sweden.
- Raysearch Laboratories AB, Stockholm, Sweden.
Zitieren
APA
Kalholm, F., Toma-Dasu, I., & Traneus, E. (2025). ‘Dirty dose’‐based proton variable RBE models ‐ performance assessment on in vitro data. Medical Physics. https://doi.org/10.1002/mp.17519
Vancouver
Kalholm F, Toma-Dasu I, Traneus E. ‘Dirty dose’‐based proton variable RBE models ‐ performance assessment on in vitro data. Medical Physics. 2025. doi:10.1002/mp.17519
BibTeX
@article{Kalholm2025,
author = {Kalholm, Fredrik and Toma-Dasu, Iuliana and Traneus, Erik},
title = {‘Dirty dose’‐based proton variable RBE models ‐ performance assessment on in vitro data},
journal = {Medical Physics},
year = {2025},
doi = {10.1002/mp.17519}
}
EUVIMED