Automated cardiac coverage assessment in cardiovascular magnetic resonance imaging using an explainable recurrent 3D dual‐domain convolutional network
Medical Physics · 2024
DOI: 10.1002/mp.17411 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, 2024. Verfasst von Shahabedin Nabavi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Computer Science and Engineering, Shahid Beheshti University, Tehran, Iran. Hauptthemen laut MEDLINE: Automation, Magnetic Resonance Imaging, Heart, Imaging, Three-Dimensional. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 39 Literaturangaben.
Abstract (Originalsprache)
Background
Cardiovascular magnetic resonance (CMR) imaging has become a modality with superior power for the diagnosis and prognosis of cardiovascular diseases. One of the essential quality controls of CMR images is to investigate the complete cardiac coverage, which is necessary for the volumetric and functional assessment.
Purpose
This study examines the full cardiac coverage using a 3D dual‐domain convolutional model and then improves this model using an innovative explainable salient region detection model and a recurrent architecture.
Methods
Salient regions are extracted from the short‐axis cine CMR stacks using a three‐step proposed algorithm. Changing the architecture of the 3D dual‐domain convolutional model to a recurrent one and taking advantage of the salient region detection model creates a kind of attention mechanism that leads to improved results.
Results
The results obtained from the images of over 6200 participants of the UK Biobank population cohort study show the superiority of the proposed model over the previous studies. The dataset is the largest regarding the number of participants to control the cardiac coverage. The accuracies of the proposed model in identifying the presence/absence of basal/apical slices are 96.22% and 95.42%, respectively.
Conclusion
The proposed recurrent architecture of the 3D dual‐domain convolutional model can force the model to focus on the most informative areas of the images using the extracted salient regions, which can help the model improve accuracy. The performance of the proposed fully automated model indicates that it can be used for image quality control in population cohort datasets and real‐time post‐imaging quality assessments. Codes are available at https://github.com/mohammadhashemii/CMR_Cardiac_Coverage_Control
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Computer Science and Engineering, Shahid Beheshti University, Tehran, Iran.
- Christable Pankhurst Institute, Division of Informatics, Imaging and Data Sciences, School of Health Sciences, and Department of Computer Science, School of Engineering, The University of Manchester, Manchester, UK.
- Medical Imaging Research Center (MIRC), Department of Electrical Engineering and Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium.
- Alan Turing Institute, London, UK.
Zitieren
APA
Nabavi, S., Hashemi, M., Ebrahimi Moghaddam, M., Abin, A. A., & Frangi, A. F. (2024). Automated cardiac coverage assessment in cardiovascular magnetic resonance imaging using an explainable recurrent 3D dual‐domain convolutional network. Medical Physics. https://doi.org/10.1002/mp.17411
Vancouver
Nabavi S, Hashemi M, Ebrahimi Moghaddam M, Abin AA, Frangi AF. Automated cardiac coverage assessment in cardiovascular magnetic resonance imaging using an explainable recurrent 3D dual‐domain convolutional network. Medical Physics. 2024. doi:10.1002/mp.17411
BibTeX
@article{Nabavi2024,
author = {Nabavi, Shahabedin and Hashemi, Mohammad and Ebrahimi Moghaddam, Mohsen and Abin, Ahmad Ali and Frangi, Alejandro F},
title = {Automated cardiac coverage assessment in cardiovascular magnetic resonance imaging using an explainable recurrent 3D dual‐domain convolutional network},
journal = {Medical Physics},
year = {2024},
doi = {10.1002/mp.17411}
}
EUVIMED