Deep learning‐based dose prediction for magnetic resonance‐guided prostate radiotherapy
Medical Physics · 2024
DOI: 10.1002/mp.17312 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, 2024. Verfasst von Samuel Fransson und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics, Uppsala University Hospital, Uppsala, Sweden. Hauptthemen laut MEDLINE: Deep Learning, Prostatic Neoplasms, Radiotherapy Dosage, Radiotherapy, Image-Guided. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: ASSIST.
Abstract (Originalsprache)
Background
Daily adaptive radiotherapy, as performed with the Elekta Unity MR‐Linac, requires choosing between different adaptation methods, namely ATP (Adapt to Position) and ATS (Adapt to Shape), where the latter requires daily re‐contouring to obtain a dose plan tailored to the daily anatomy. These steps are inherently resource‐intensive, and quickly predicting the dose distribution and the dosimetric evaluation criteria while the patient is on the table could facilitate a fast selection of adaptation method and decrease the treatment times.
Purpose
In this work, we aimed to develop a deep‐learning‐based dose‐prediction pipeline for prostate MR‐Linac treatments.
Methods
Two hundred twelve MR‐images, structure sets, and dose distributions from 35 prostate patients treated with 6.1 Gy for 7 or 6 fractions at our MR‐Linac were included, split into train/test partitions of 152/60 images, respectively. A deep‐learning segmentation network was trained to segment the CTV (prostate), bladder, and rectum. A second network was trained to predict the dose distribution based on manually delineated structures. At inference, the predicted segmentations acted as input to the dose prediction network, and the predicted dose was compared to the true (optimized in the treatment planning system) dose distribution.
Results
Median DSC values from the segmentation network were 0.90/0.94/0.87 for CTV/bladder/rectum. Predicted segmentations as input to the dose prediction resulted in mean differences between predicted and true doses of 0.7%/0.7%/1.7% (relative to the prescription dose) for D 98% / D 95% / D 2% for the CTV. For the bladder, the difference was 0.7%/0.3% for D mean /D 2% and for the rectum 0.1/0.2/0.2 pp (percentage points) for V 33Gy / V 38Gy / V 41Gy . In comparison, true segmentations as input resulted in differences of 1.1%/0.9%/1.6% for CTV, 0.5%/0.4% for bladder, and 0.7/0.4/0.3 pp for the rectum. Only D 2% for CTV and D mean / D 2% for bladder were found to be statistically significantly better when using true structures instead of predicted structures as input to the dose prediction.
Conclusions
Small differences in the fulfillment of clinical dose‐volume constraints are seen between utilizing deep‐learning predicted structures as input to a dose prediction network and manual structures. Overall mean differences 2%.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Physics, Uppsala University Hospital, Uppsala, Sweden.
- Department of Surgical Sciences, Uppsala University, Uppsala, Sweden.
- Department of Information Technology, Uppsala University, Uppsala, Sweden.
- Department of Immunology, Genetics and Pathology, Uppsala University, Uppsala, Sweden.
Förderung
- ASSIST
Zitieren
APA
Fransson, S., Strand, R., & Tilly, D. (2024). Deep learning‐based dose prediction for magnetic resonance‐guided prostate radiotherapy. Medical Physics. https://doi.org/10.1002/mp.17312
Vancouver
Fransson S, Strand R, Tilly D. Deep learning‐based dose prediction for magnetic resonance‐guided prostate radiotherapy. Medical Physics. 2024. doi:10.1002/mp.17312
BibTeX
@article{Fransson2024,
author = {Fransson, Samuel and Strand, Robin and Tilly, David},
title = {Deep learning‐based dose prediction for magnetic resonance‐guided prostate radiotherapy},
journal = {Medical Physics},
year = {2024},
doi = {10.1002/mp.17312}
}