A generalized model of cardiac surface motion for evaluating left anterior descending coronary artery dose in left breast cancer radiotherapy
Medical Physics · 2024
DOI: 10.1002/mp.17261 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, 2024. Verfasst von Yongjin Deng und 7 weiteren Autor:innen. Beteiligte Einrichtung: The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, Guangdong Province, PR China. Hauptthemen laut MEDLINE: Coronary Vessels, Breast Neoplasms. Die Arbeit nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Retrospective studies indicate that radiation damage to left anterior descending coronary artery (LAD) may be critical for late‐stage radiation‐induced cardiac morbidity. Developing a method that accurately depicts LAD motion and perform dose assessment is crucial.
Purpose
To construct a generalized cardiac surface motion model for LAD dose assessment in left breast cancer radiotherapy.
Methods
Cine MRI of 25 cases were divided into training and testing sets for model construction, and five external cases were gathered for generalization validation. Motion prediction from average intensity projection images (AIP) surface point cloud to that of each phase was realized by mapping the relationship between datum points and corresponding points with statistical shape modeling (SSM). Root mean square error (RMSE) for predicted corresponding points and Euclidean distance (ED) for predicted surface point cloud were used to assess model's accuracy. LAD dose assessment for 10 left breast cancer radiotherapy cases was perform by model application.
Results
The RMSE in testing cases and external cases were 0.209 ± 0.020 mm to 0.841 ± 0.074 mm and 0.895 ± 0.093 mm to 1.912 ± 0.138 mm, respectively; while the ED were 1.399 ± 0.029 mm to 1.658 ± 0.100 mm, 1.571 ± 0.080 mm to 1.779 ± 0.104 mm, respectively, proving the generalized model's high accuracy. The volume of LAD characterizing motion range (WPLAD) (2.392 ± 0.639 cm 3 ) was approximately twice that of LAD from superimposed images (SPLAD) (0.927 ± 0.326 cm 3 ) with p < 0.05, and the former's Dmax (3582.06 ± 575.92 cGy) was significantly larger than latter's (3222.71 ± 665.37 cGy) ( p < 0.05). While WPLAD's Dmean (1408.06 ± 413.06 cGy) was slightly smaller than that of SPLAD (1504.15 ± 448.03 cGy), the difference did not reach statistical significance ( p > 0.05). WPLAD's V20 (23.42% ± 16.62%) was less than SPLAD's (29.18% ± 21.07%) with p < 0.05, but their comparison in V30 and V40 did not yield statistically significant results. It implies the conventional LAD dose assessment ignores motion impact and may not be justified.
Conclusions
The generalized cardiac surface motion model informs LAD dose accurate assessment in left breast cancer radiotherapy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, Guangdong Province, PR China.
Zitieren
APA
Deng, Y., Qiu, M., Li, Y., Wang, C., Zhong, J., Xiao, Z., Wang, C., & Chen, R. (2024). A generalized model of cardiac surface motion for evaluating left anterior descending coronary artery dose in left breast cancer radiotherapy. Medical Physics. https://doi.org/10.1002/mp.17261
Vancouver
Deng Y, Qiu M, Li Y, Wang C, Zhong J, Xiao Z, et al. A generalized model of cardiac surface motion for evaluating left anterior descending coronary artery dose in left breast cancer radiotherapy. Medical Physics. 2024. doi:10.1002/mp.17261
BibTeX
@article{Deng2024,
author = {Deng, Yongjin and Qiu, Minmin and Li, Yangchan and Wang, Chaoyang and Zhong, Jiajian and Xiao, Zhenhua and Wang, Chengtao and Chen, Ruiwan},
title = {A generalized model of cardiac surface motion for evaluating left anterior descending coronary artery dose in left breast cancer radiotherapy},
journal = {Medical Physics},
year = {2024},
doi = {10.1002/mp.17261}
}
EUVIMED