MPIGAN: An end‐to‐end deep based generative framework for high‐resolution magnetic particle imaging reconstruction
Medical Physics · 2024
DOI: 10.1002/mp.17104 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, 2024. Verfasst von Jing Zhao und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Engineering Medicine, Beihang University, Beijing, China. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 66 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Beijing Hospital Authority Clinical Medicine Development Special Funding.
Abstract (Originalsprache)
Background
Magnetic particle imaging (MPI) is a recently developed, non‐invasive in vivo imaging technique to map the spatial distribution of superparamagnetic iron oxide nanoparticles (SPIONs) in animal tissues with high sensitivity and speed. It is a challenge to reconstruct images directly from the received signals of MPI device due to the complex physical behavior of the nanoparticles. System matrix and X‐space are two commonly used MPI reconstruction methods, where the former is extremely time‐consuming and the latter usually produces blurry images.
Purpose
Currently, we proposed an end‐to‐end machine learning framework to reconstruct high‐resolution MPI images from 1‐D voltage signals directly and efficiently.
Methods
The proposed framework, which we termed “MPIGAN”, was trained on a large MPI simulation dataset containing 291 597 pairs of high‐resolution 2‐D phantom images and each image's corresponding voltage signals, so that it was able to accurately capture the nonlinear relationship between the spatial distribution of SPIONs and the received voltage signal, and realized high‐resolution MPI image reconstruction.
Results
Experiment results showed that, MPIGAN exhibited remarkable abilities in high‐resolution MPI image reconstruction. MPIGAN outperformed the traditional methods of system matrix and X‐space in recovering the fine‐scale structure of magnetic nanoparticles’ spatial distribution and achieving enhanced reconstruction performance in both visual effects and quantitative assessments. Moreover, even when the received signals were severely contaminated with noise, MPIGAN could still generate high‐quality MPI images.
Conclusion
Our study provides a promising AI solution for end‐to‐end, efficient, and high‐resolution magnetic particle imaging reconstruction.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Engineering Medicine, Beihang University, Beijing, China.
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China.
- School of Computer Science and Engineering, Southeast University, Nanjing, China.
- School of Psychological and Cognitive Sciences, Peking University, Beijing, China.
- Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beihang University, Beijing, China.
- Key Laboratory of Big Data-Based Precision Medicine, Ministry of Industry and Information Technology of the People's Republic of China, Beihang University, Beijing, China.
Förderung
- National Natural Science Foundation of China
- Beijing Hospital Authority Clinical Medicine Development Special Funding
Zitieren
APA
Zhao, J., Shen, Y., Liu, X., Hou, X., Ding, X., An, Y., Hui, H., Tian, J., & Zhang, H. (2024). MPIGAN: An end‐to‐end deep based generative framework for high‐resolution magnetic particle imaging reconstruction. Medical Physics. https://doi.org/10.1002/mp.17104
Vancouver
Zhao J, Shen Y, Liu X, Hou X, Ding X, An Y, et al. MPIGAN: An end‐to‐end deep based generative framework for high‐resolution magnetic particle imaging reconstruction. Medical Physics. 2024. doi:10.1002/mp.17104
BibTeX
@article{Zhao2024,
author = {Zhao, Jing and Shen, Yusong and Liu, Xinyi and Hou, Xiaoyuan and Ding, Xuetong and An, Yu and Hui, Hui and Tian, Jie and Zhang, Hui},
title = {MPIGAN: An end‐to‐end deep based generative framework for high‐resolution magnetic particle imaging reconstruction},
journal = {Medical Physics},
year = {2024},
doi = {10.1002/mp.17104}
}
EUVIMED