EUVIMEDEUVIMED entdecken
Open Access

Full‐dose whole‐body PET synthesis from low‐dose PET using high‐efficiency denoising diffusion probabilistic model: PET consistency model

Shaoyan Pan, Elham Abouei, Junbo Peng, Joshua Qian, Jacob F Wynne, Tonghe Wang, Chih-Wei Chang, Justin Roper, Jonathon A Nye, Hui Mao, Xiaofeng Yang

Medical Physics · 2024-08 · 51 (8) · 5468-5478

DOI: 10.1002/mp.17068 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, online erschienen am 08.04.2024. Verfasst von Shaoyan Pan und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA. Hauptthemen laut MEDLINE: Positron-Emission Tomography, Signal-To-Noise Ratio, Radiation Dosage, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 36-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, NIH HHS, NIBIB NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Positron Emission Tomography (PET) has been a commonly used imaging modality in broad clinical applications. One of the most important tradeoffs in PET imaging is between image quality and radiation dose: high image quality comes with high radiation exposure. Improving image quality is desirable for all clinical applications while minimizing radiation exposure is needed to reduce risk to patients.

Methods

We introduce PET Consistency Model (PET‐CM), an efficient diffusion‐based method for generating high‐quality full‐dose PET images from low‐dose PET images. It employs a two‐step process, adding Gaussian noise to full‐dose PET images in the forward diffusion, and then denoising them using a PET Shifted‐window Vision Transformer (PET‐VIT) network in the reverse diffusion. The PET‐VIT network learns a consistency function that enables direct denoising of Gaussian noise into clean full‐dose PET images. PET‐CM achieves state‐of‐the‐art image quality while requiring significantly less computation time than other methods. Evaluation with normalized mean absolute error (NMAE), peak signal‐to‐noise ratio (PSNR), multi‐scale structure similarity index (SSIM), normalized cross‐correlation (NCC), and clinical evaluation including Human Ranking Score (HRS) and Standardized Uptake Value (SUV) Error analysis shows its superiority in synthesizing full‐dose PET images from low‐dose inputs.

Results

In experiments comparing eighth‐dose to full‐dose images, PET‐CM demonstrated impressive performance with NMAE of 1.278 ± 0.122%, PSNR of 33.783 ± 0.824 dB, SSIM of 0.964 ± 0.009, NCC of 0.968 ± 0.011, HRS of 4.543, and SUV Error of 0.255 ± 0.318%, with an average generation time of 62 s per patient. This is a significant improvement compared to the state‐of‐the‐art diffusion‐based model with PET‐CM reaching this result 12× faster. Similarly, in the quarter‐dose to full‐dose image experiments, PET‐CM delivered competitive outcomes, achieving an NMAE of 0.973 ± 0.066%, PSNR of 36.172 ± 0.801 dB, SSIM of 0.984 ± 0.004, NCC of 0.990 ± 0.005, HRS of 4.428, and SUV Error of 0.151 ± 0.192% using the same generation process, which underlining its high quantitative and clinical precision in both denoising scenario.

Conclusions

We propose PET‐CM, the first efficient diffusion‐model‐based method, for estimating full‐dose PET images from low‐dose images. PET‐CM provides comparable quality to the state‐of‐the‐art diffusion model with higher efficiency. By utilizing this approach, it becomes possible to maintain high‐quality PET images suitable for clinical use while mitigating the risks associated with radiation. The code is availble at https://github.com/shaoyanpan/Full‐dose‐Whole‐body‐PET‐Synthesis‐from‐Low‐dose‐PET‐Using‐Consistency‐Model .

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Positron-Emission TomographySignal-To-Noise RatioRadiation DosageImage Processing, Computer-AssistedModels, StatisticalHumansDiffusionWhole Body Imaging

Stichwörter der Autor:innen

PET synthesisSwin transformerconsistency modeldenoising diffusion probabilistic modelimage synthesis

Autor:innen und Institutionen

  • Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.
  • Department of Biomedical Informatics, Emory University, Atlanta, Georgia, USA.
  • Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
  • Radiology and Radiological Science, Medical University of South Carolina, Charleston, South Carolina, USA.
  • Department of Radiology and Imaging Science, and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.

Förderung

  • NCI NIH HHS
  • NIH HHS
  • NIBIB NIH HHS
  • National Institutes of Health

Zitieren

APA

Pan, S., Abouei, E., Peng, J., Qian, J., Wynne, J. F., Wang, T., Chang, C. W., Roper, J., Nye, J. A., Mao, H., & Yang, X. (2024). Full‐dose whole‐body PET synthesis from low‐dose PET using high‐efficiency denoising diffusion probabilistic model: PET consistency model. Medical Physics, 51(8), 5468-5478. https://doi.org/10.1002/mp.17068

Vancouver

Pan S, Abouei E, Peng J, Qian J, Wynne JF, Wang T, et al. Full‐dose whole‐body PET synthesis from low‐dose PET using high‐efficiency denoising diffusion probabilistic model: PET consistency model. Medical Physics. 2024;51(8):5468-5478. doi:10.1002/mp.17068

BibTeX
@article{Pan2024,
  author = {Pan, Shaoyan and Abouei, Elham and Peng, Junbo and Qian, Joshua and Wynne, Jacob F and Wang, Tonghe and Chang, Chih-Wei and Roper, Justin and Nye, Jonathon A and Mao, Hui and Yang, Xiaofeng},
  title = {Full‐dose whole‐body PET synthesis from low‐dose PET using high‐efficiency denoising diffusion probabilistic model: PET consistency model},
  journal = {Medical Physics},
  year = {2024},
  volume = {51},
  number = {8},
  pages = {5468--5478},
  doi = {10.1002/mp.17068}
}
Kostenlos starten →