Development and benchmarking of a dose rate engine for raster‐scanned FLASH helium ions
Medical Physics · 2024
DOI: 10.1002/mp.16793 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, 2024. Verfasst von Luisa Rank und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, Heidelberg, Germany. Hauptthemen laut MEDLINE: Helium, Proton Therapy. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, National Science Foundation.
Abstract (Originalsprache)
Background
Radiotherapy with charged particles at high dose and ultra‐high dose rate (uHDR) is a promising technique to further increase the therapeutic index of patient treatments. Dose rate is a key quantity to predict the so‐called FLASH effect at uHDR settings. However, recent works introduced varying calculation models to report dose rate, which is susceptible to the delivery method, scanning path (in active beam delivery) and beam intensity.
Purpose
This work introduces an analytical dose rate calculation engine for raster scanned charged particle beams that is able to predict dose rate from the irradiation plan and recorded beam intensity. The importance of standardized dose rate calculation methods is explored here.
Methods
Dose is obtained with an analytical pencil beam algorithm, using pre‐calculated databases for integrated depth dose distributions and lateral penumbra. Dose rate is then calculated by combining dose information with the respective particle fluence (i.e., time information) using three dose‐rate‐calculation models (mean, instantaneous, and threshold‐based). Dose rate predictions for all three models are compared to uHDR helium ion beam (145.7 MeV/u, range in water of approximatively 14.6 cm) measurements performed at the Heidelberg Ion Beam Therapy Center (HIT) with a diamond‐detector prototype. Three scanning patterns (scanned or snake‐like) and four field sizes are used to investigate the dose rate differences.
Results
Dose rate measurements were in good agreement with in‐silico generated distributions using the here introduced engine. Relative differences in dose rate were below 10% for varying depths in water, from 2.3 to 14.8 cm, as well as laterally in a near Bragg peak area. In the entrance channel of the helium ion beam, dose rates were predicted within 7% on average for varying irradiated field sizes and scanning patterns. Large differences in absolute dose rate values were observed for varying calculation methods. For raster‐scanned irradiations, the deviation between mean and threshold‐based dose rate at the investigated point was found to increase with the field size up to 63% for a 10 mm × 10 mm field, while no significant differences were observed for snake‐like scanning paths.
Conclusions
This work introduces the first dose rate calculation engine benchmarked to instantaneous dose rate, enabling dose rate predictions for physical and biophysical experiments. Dose rate is greatly affected by varying particle fluence, scanning path, and calculation method, highlighting the need for a consensus among the FLASH community on how to calculate and report dose rate in the future. The here introduced engine could help provide the necessary details for the analysis of the sparing effect and uHDR conditions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiation Oncology, Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, Heidelberg, Germany.
- Faculty of Physics, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany.
- Faculty of Physics and Astronomy, Heidelberg University, Heidelberg, Germany.
- Clinical Cooperation Unit Translational Radiation Oncology, German Cancer Consortium (DKTK) Core-Center Heidelberg, National Center for Tumor Diseases (NCT), Heidelberg University Hospital (UKHD) and German Cancer Resea…
- Division of Molecular and Translational Radiation Oncology, Heidelberg Faculty of Medicine (MFHD) and Department of Radiation Oncology, Heidelberg University Hospital (UKHD), Heidelberg, Germany.
- Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg University Hospital (UKHD), Heidelberg Faculty of Medicine (MFHD) and German Cancer Research Center (DKFZ), He…
Förderung
- NCI NIH HHS
- National Science Foundation
Zitieren
APA
Rank, L., Dogan, O., Kopp, B., Mein, S., Verona-Rinati, G., Kranzer, R., Marinelli, M., Mairani, A., & Tessonnier, T. (2024). Development and benchmarking of a dose rate engine for raster‐scanned FLASH helium ions. Medical Physics. https://doi.org/10.1002/mp.16793
Vancouver
Rank L, Dogan O, Kopp B, Mein S, Verona-Rinati G, Kranzer R, et al. Development and benchmarking of a dose rate engine for raster‐scanned FLASH helium ions. Medical Physics. 2024. doi:10.1002/mp.16793
BibTeX
@article{Rank2024,
author = {Rank, Luisa and Dogan, Ozan and Kopp, Benedikt and Mein, Stewart and Verona-Rinati, Gianluca and Kranzer, Rafael and Marinelli, Marco and Mairani, Andrea and Tessonnier, Thomas},
title = {Development and benchmarking of a dose rate engine for raster‐scanned FLASH helium ions},
journal = {Medical Physics},
year = {2024},
doi = {10.1002/mp.16793}
}
EUVIMED