Fachartikel in der Zeitschrift Medical Physics, 2024. Verfasst von Luke Matkovic und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA. Hauptthemen laut MEDLINE: Four-Dimensional Computed Tomography, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIH HHS, NCI NIH HHS, NIBIB NIH HHS.
Abstract (Originalsprache)
Background
An automated, accurate, and efficient lung four‐dimensional computed tomography (4DCT) image registration method is clinically important to quantify respiratory motion for optimal motion management.
Purpose
The purpose of this work is to develop a weakly supervised deep learning method for 4DCT lung deformable image registration (DIR).
Methods
The landmark‐driven cycle network is proposed as a deep learning platform that performs DIR of individual phase datasets in a simulation 4DCT. This proposed network comprises a generator and a discriminator. The generator accepts moving and target CTs as input and outputs the deformation vector fields (DVFs) to match the two CTs. It is optimized during both forward and backward paths to enhance the bi‐directionality of DVF generation. Further, the landmarks are used to weakly supervise the generator network. Landmark‐driven loss is used to guide the generator's training. The discriminator then judges the realism of the deformed CT to provide extra DVF regularization.
Results
We performed four‐fold cross‐validation on 10 4DCT datasets from the public DIR‐Lab dataset and a hold‐out test on our clinic dataset, which included 50 4DCT datasets. The DIR‐Lab dataset was used to evaluate the performance of the proposed method against other methods in the literature by calculating the DIR‐Lab Target Registration Error (TRE). The proposed method outperformed other deep learning‐based methods on the DIR‐Lab datasets in terms of TRE. Bi‐directional and landmark‐driven loss were shown to be effective for obtaining high registration accuracy. The mean and standard deviation of TRE for the DIR‐Lab datasets was 1.20 ± 0.72 mm and the mean absolute error (MAE) and structural similarity index (SSIM) for our datasets were 32.1 ± 11.6 HU and 0.979 ± 0.011, respectively.
Conclusion
The landmark‐driven cycle network has been validated and tested for automatic deformable image registration of patients’ lung 4DCTs with results comparable to or better than competing methods.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
Förderung
- NIH HHS
- NCI NIH HHS
- NIBIB NIH HHS
- National Institutes of Health
Zitieren
APA
Matkovic, L., Lei, Y., Fu, Y., Wang, T., Kesarwala, A. H., Axente, M., Roper, J., Higgins, K., Bradley, J. D., Liu, T., & Yang, X. (2024). Deformable lung 4DCT image registration via landmark‐driven cycle network. Medical Physics. https://doi.org/10.1002/mp.16738
Vancouver
Matkovic L, Lei Y, Fu Y, Wang T, Kesarwala AH, Axente M, et al. Deformable lung 4DCT image registration via landmark‐driven cycle network. Medical Physics. 2024. doi:10.1002/mp.16738
BibTeX
@article{Matkovic2024,
author = {Matkovic, Luke and Lei, Yang and Fu, Yabo and Wang, Tonghe and Kesarwala, Aparna H and Axente, Marian and Roper, Justin and Higgins, Kristin and Bradley, Jeffrey D and Liu, Tian and Yang, Xiaofeng},
title = {Deformable lung 4DCT image registration via landmark‐driven cycle network},
journal = {Medical Physics},
year = {2024},
doi = {10.1002/mp.16738}
}
EUVIMED