FLASH dose rate calculation based on log files in proton pencil beam scanning therapy

Chanil Jeon, Sunghwan Ahn, Daizo Amano, Nagaaki Kamiguchi, Sungkoo Cho, Heesoon Sheen, Hee Chul Park, Youngyih Han

Medical Physics · 2023

DOI: 10.1002/mp.16575 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2023. Verfasst von Chanil Jeon und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health Sciences and Technology, SAIHST, Sungkyunkwan University, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Protons, Proton Therapy. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: National Research Foundation of Korea (NRF) and the Korean government (MSIT).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

In radiation therapy, irradiating healthy normal tissues in the beam trajectories is inevitable. This unnecessary dose means that patients undergoing treatment risk developing side effects. Recently, FLASH radiotherapy delivering ultra‐high‐dose‐rate beams has been re‐examined because of its normal‐tissue‐sparing effect. To confirm the mean and instantaneous dose rates of the FLASH beam, stable and accurate dosimetry is required.

Purpose

Detailed verification of the FLASH effect requires dosimeters and a method to measure the average and instantaneous dose rate stably for 2‐ or 3‐dimensional dose distributions. To verify the delivered FLASH beam, we utilized machine log files from the built‐in monitor chamber to develop a dosimetry method to calculate the dose and average/instantaneous dose rate distributions in two or three dimensions in a phantom.

Methods

To create a spread‐out Bragg peak (SOBP) and deliver a uniform dose in a target, a mini‐ridge filter was created with a 3D printer. Proton pencil beam line scanning plans of 2 × 2 cm 2 , 3 × 3 cm 2 , 4 × 4 cm 2 , and round shapes with 2.3 cm diameter patterns delivering 230 MeV energy protons were created. The absorbed dose in the solid water phantom of each plan was measured using a PPC05 ionization chamber (IBA Dosimetry, Virginia, USA) in the SOBP region, and the log files for each plan were exported from the treatment control system console. Using these log files, the delivered dose and average dose rate were calculated using two methods: a direct method and a Monte Carlo (MC) simulation method that uses log file information. The computed and average dose rates were compared with the ionization chamber measurements. Additionally, instantaneous dose rates in user‐defined volumes were calculated using the MC simulation method with a temporal resolution of 5 ms.

Results

Compared to ionization chamber dosimetry, 10 of 12 cases using the direct calculation method and 9 of 11 cases using the MC method had a dose difference below ±3%. Nine of 12 cases using the direct calculation method and 8 of 11 cases using the MC method had dose rate differences below ±3%. The average and maximum dose differences for the direct calculation and MC method were–0.17, +0.72%, and −3.15, +3.32%, respectively. For the dose rate difference, the average and maximum for the direct calculation and MC method were +1.26, +1.12%, and +3.75, +3.15%, respectively. In the instantaneous dose rate calculation with the MC simulation, a large fluctuation with a maximum of 163 Gy/s and a minimum of 4.29 Gy/s instantaneous dose rate was observed in a specific position, whereas the mean dose rate was 62 Gy/s.

Conclusions

We successfully developed methods in which machine log files are used to calculate the dose and the average and instantaneous dose rates for FLASH radiotherapy and demonstrated the feasibility of verifying the delivered FLASH beams.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ProtonsProton TherapyHumansRadiotherapy DosageRadiotherapy Planning, Computer-AssistedRadiometryMonte Carlo Method

Substanzen

Protons

Autor:innen und Institutionen

  • Department of Health Sciences and Technology, SAIHST, Sungkyunkwan University, Seoul, Republic of Korea.
  • Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
  • Sumitomo Heavy Industries, Ltd, Tokyo, Japan.

Förderung

  • National Research Foundation of Korea (NRF) and the Korean government (MSIT)

Zitieren

APA

Jeon, C., Ahn, S., Amano, D., Kamiguchi, N., Cho, S., Sheen, H., Park, H. C., & Han, Y. (2023). FLASH dose rate calculation based on log files in proton pencil beam scanning therapy. Medical Physics. https://doi.org/10.1002/mp.16575

Vancouver

Jeon C, Ahn S, Amano D, Kamiguchi N, Cho S, Sheen H, et al. FLASH dose rate calculation based on log files in proton pencil beam scanning therapy. Medical Physics. 2023. doi:10.1002/mp.16575

BibTeX
@article{Jeon2023,
  author = {Jeon, Chanil and Ahn, Sunghwan and Amano, Daizo and Kamiguchi, Nagaaki and Cho, Sungkoo and Sheen, Heesoon and Park, Hee Chul and Han, Youngyih},
  title = {FLASH dose rate calculation based on log files in proton pencil beam scanning therapy},
  journal = {Medical Physics},
  year = {2023},
  doi = {10.1002/mp.16575}
}
Kostenlos starten →