Lattice position optimization for LATTICE therapy
Medical Physics · 2023-12 · 50 (12) · 7359-7367
DOI: 10.1002/mp.16572 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, online erschienen am 26.06.2023. Verfasst von Weijie Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, University of Kansas Medical Center, Lawrence, Kansas, USA. Hauptthemen laut MEDLINE: Neoplasms, Radiotherapy, Intensity-Modulated, Proton Therapy. Die Arbeit wurde bisher 58-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
Background
LATTICE radiation therapy delivers 3D heterogenous dose of high peak‐to‐valley dose ratio (PVDR) to the tumor target, with peak dose at lattice vertices inside the target and valley dose for the rest of the target. Although the lattice vertex positions can impact PVDR inside the target and sparing of organs‐at‐risk (OAR), they are fixed as constants and not optimized during treatment planning in current clinical practice.
Purpose
This work proposes a new LATTICE plan optimization method that can optimize lattice vertex positions during LATTICE treatment planning, which is the first lattice position optimization study to the best of our knowledge.
Methods
The new LATTICE treatment planning method optimizes lattice vertex positions as well as other plan variables (e.g., photon fluences or proton spot weights), with optimization objectives for target PVDR and OAR sparing. To satisfy mathematical differentiability, the lattice vertices are approximated in sigmoid functions. For geometric feasibility, proper geometry constraints are enforced onto lattice vertex positions. The lattice position optimization problem is solved by iterative convex relaxation (ICR) method and alternating direction method of multipliers (ADMM), and lattice vertex positions and photon/proton plan variables are jointly updated via the Quasi‐Newton method.
Results
Both photon and proton LATTICE RT were considered, and the optimal lattice vertex positions in terms of plan objectives were found by solving all possible combinations on given discrete positions via exhaustive searching based on standard IMRT/IMPT, which served as the ground truth for validating the new LATTICE method. The results show that the new method indeed provided the optimal lattice vertex positions with the smallest optimization objective, the largest target PVDR, and the best OAR sparing.
Conclusions
A new LATTICE treatment planning method is proposed and validated that can optimize lattice vertex positions as well as other photon or proton plan variables for improving target PVDR and OAR sparing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiation Oncology, University of Kansas Medical Center, Lawrence, Kansas, USA.
Förderung
- NCI NIH HHS
- NIH HHS
- National Institutes of Health
Zitieren
APA
Zhang, W., Lin, Y., Wang, F., Badkul, R., Chen, R. C., & Gao, H. (2023). Lattice position optimization for LATTICE therapy. Medical Physics, 50(12), 7359-7367. https://doi.org/10.1002/mp.16572
Vancouver
Zhang W, Lin Y, Wang F, Badkul R, Chen RC, Gao H. Lattice position optimization for LATTICE therapy. Medical Physics. 2023;50(12):7359-7367. doi:10.1002/mp.16572
BibTeX
@article{Zhang2023,
author = {Zhang, Weijie and Lin, Yuting and Wang, Fen and Badkul, Rajeev and Chen, Ronald C and Gao, Hao},
title = {Lattice position optimization for LATTICE therapy},
journal = {Medical Physics},
year = {2023},
volume = {50},
number = {12},
pages = {7359--7367},
doi = {10.1002/mp.16572}
}
EUVIMED