Impact of uptake time on image quality of [ 68 Ga]Ga‐PSMA‐11 PET/CT
Medical Physics · 2023
DOI: 10.1002/mp.16429 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, 2023. Verfasst von Esmée C A van der Sar und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Bone Neoplasms. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
With the introduction of prostate specific membrane antigen (PSMA) PET/CT, the detection rate of prostate cancer metastases has improved significantly, both for primary staging and for biochemical recurrence. EANM/SNMMI guidelines recommend a 60 min time interval between [ 68 Ga]Ga‐PSMA administration and acquisition.
Purpose
This study evaluates the possibility of a shorter time interval by investigating the dynamic change in image quality measures.
Method
We retrospectively analyzed 10 consecutive prostate cancer patients who underwent a dynamic whole body [ 68 Ga]Ga‐PSMA‐11 PET/CT of 75 min from skull vertex to mid‐thigh using Siemens FlowMotion. PET images were acquired directly after injection of 1.5 MBq/kg [ 68 Ga]Ga‐PSMA‐11. Image quality measures included lesion maximum standardized uptake value corrected for lean body mass (SUL max ), tumor‐to‐background ratio (TBR), and contrast‐to‐noise ratio (CNR). Quantitative analysis of image quality in dynamic PET was performed using PMOD (version 4.2). Regions of interest (ROIs), drawn included different types of prostate lesions (primary tumor, lymph nodes, and bone metastasis), organ tissue (liver, spleen, lacrimal gland, submandibular gland, parotid gland, urinary bladder, kidneys blood pool [ascending aorta], left ventricle), bone tissue (4th lumbar vertebral body [L4]) and muscle tissue (gluteus maximus). To further investigate image quality four 10 min multi‐frame reconstructions with clinical parameters were made at different post‐injection times (15, 30, 45, and 60 min). A nuclear medicine physician performed a blinded lesion detectability evaluation on these multi‐frame reconstructions for different prostate cancer lesions.
Results
Six primary prostate tumors in seven patients with prostate in situ, 13 lymph node metastases in six patients and up to 12 bone metastases in three patients were found. The different prostate lesion types (lymph nodes metastases, bone metastases, and primary prostate tumor) all show an increase in average SUL max , TBR, and CNR over time during the scan. The normalized average SUL max , TBR, and CNR of the combined prostate lesions at 15, 30, and 45 min post‐injection scans were all significant p < 0.05 lower from the 60 min post‐injection [ 68 Ga]Ga‐PSMA‐11 PET/CT (9.5 ± 4.5, 12.7 ± 6.2, and 41.8 ± 24.5, respectively). At patient level, the reader concluded the same regarding the presence/absence of primary prostate cancer recurrence, lymph node metastases, and/or bone metastases on all
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands.
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Center, Amsterdam, The Netherlands.
ORCID-Profile: Esmée C A van der Sar, Sebastiaan L Meyer Viol, Arthur J A T Braat, Rob van Rooij, Marnix G E H Lam, Hugo W A M de Jong, Bart de Keizer
Zitieren
APA
van der Sar, E. C. A., Viol, S. L. M., Braat, A. J. A. T., van Rooij, R., Lam, M. G. E. H., de Jong, H. W. A. M., & de Keizer, B. (2023). Impact of uptake time on image quality of [ 68 Ga]Ga‐PSMA‐11 PET/CT. Medical Physics. https://doi.org/10.1002/mp.16429
Vancouver
van der Sar ECA, Viol SLM, Braat AJAT, van Rooij R, Lam MGEH, de Jong HWAM, et al. Impact of uptake time on image quality of [ 68 Ga]Ga‐PSMA‐11 PET/CT. Medical Physics. 2023. doi:10.1002/mp.16429
BibTeX
@article{vanderSar2023,
author = {van der Sar, Esmée C A and Viol, Sebastiaan L Meyer and Braat, Arthur J A T and van Rooij, Rob and Lam, Marnix G E H and de Jong, Hugo W A M and de Keizer, Bart},
title = {Impact of uptake time on image quality of [ 68 Ga]Ga‐PSMA‐11 PET/CT},
journal = {Medical Physics},
year = {2023},
doi = {10.1002/mp.16429}
}
EUVIMED