AAPM Task Group Report 238: 3D C‐arms with volumetric imaging capability*
Medical Physics · 2023-08 · 50 (8)
DOI: 10.1002/mp.16245 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Medical Physics, online erschienen am 20.02.2023. Verfasst von Mark Supanich und 18 weiteren Autor:innen. Beteiligte Einrichtung: Rush University Medical Center, Chicago, Illinois, USA. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Radiometry. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 102 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS.
Abstract (Originalsprache)
This report reviews the image acquisition and reconstruction characteristics of C‐arm Cone Beam Computed Tomography (C‐arm CBCT) systems and provides guidance on quality control of C‐arm systems with this volumetric imaging capability. The concepts of 3D image reconstruction, geometric calibration, image quality, and dosimetry covered in this report are also pertinent to CBCT for Image‐Guided Radiation Therapy (IGRT). However, IGRT systems introduce a number of additional considerations, such as geometric alignment of the imaging at treatment isocenter, which are beyond the scope of the charge to the task group and the report. Section 1 provides an introduction to C‐arm CBCT systems and reviews a variety of clinical applications. Section 2 briefly presents nomenclature specific or unique to these systems. A short review of C‐arm fluoroscopy quality control (QC) in relation to 3D C‐arm imaging is given in Section 3. Section 4 discusses system calibration, including geometric calibration and uniformity calibration. A review of the unique approaches and challenges to 3D reconstruction of data sets acquired by C‐arm CBCT systems is give in Section 5. Sections 6 and 7 go in greater depth to address the performance assessment of C‐arm CBCT units. First, Section 6 describes testing approaches and phantoms that may be used to evaluate image quality (spatial resolution and image noise and artifacts) and identifies several factors that affect image quality. Section 7 describes both free‐in‐air and in‐phantom approaches to evaluating radiation dose indices. The methodologies described for assessing image quality and radiation dose may be used for annual constancy assessment and comparisons among different systems to help medical physicists determine when a system is not operating as expected. Baseline measurements taken either at installation or after a full preventative maintenance service call can also provide valuable data to help determine whether the performance of the system is acceptable. Collecting image quality and radiation dose data on existing phantoms used for CT image quality and radiation dose assessment, or on newly developed phantoms, will inform the development of performance criteria and standards. Phantom images are also useful for identifying and evaluating artifacts. In particular, comparing baseline data with those from current phantom images can reveal the need for system calibration before image artifacts are detected in clinical practice. Examples of artifacts are provided in Sections 4, 5, and 6.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Rush University Medical Center, Chicago, Illinois, USA.
- Johns Hopkins University, Baltimore, Maryland, USA.
- Siemens Healthineers, Forchheim, Germany.
- National Cancer Institute, Bethesda, Maryland, USA.
- Medtronic Inc., Minneapolis, Minnesota, USA.
- Philips Healthcare.
Förderung
- NCI NIH HHS
Zitieren
APA
Supanich, M., Siewerdsen, J., Fahrig, R., Farahani, K., Gang, G. J., Helm, P., Jans, J., Jones, K., Koenig, T., Kuhls-Gilcrist, A., Lin, M., Riddell, C., Ritschl, L., Schafer, S., Schueler, B., Silver, M., Timmer, J., Trousset, Y., & Zhang, J. (2023). AAPM Task Group Report 238: 3D C‐arms with volumetric imaging capability*. Medical Physics, 50(8). https://doi.org/10.1002/mp.16245
Vancouver
Supanich M, Siewerdsen J, Fahrig R, Farahani K, Gang GJ, Helm P, et al. AAPM Task Group Report 238: 3D C‐arms with volumetric imaging capability*. Medical Physics. 2023;50(8). doi:10.1002/mp.16245
BibTeX
@article{Supanich2023,
author = {Supanich, Mark and Siewerdsen, Jeff and Fahrig, Rebecca and Farahani, Keyvan and Gang, Grace Jianan and Helm, Pat and Jans, Jan and Jones, Kyle and Koenig, Thomas and Kuhls-Gilcrist, Andrew and Lin, MingDe and Riddell, Cyril and Ritschl, Ludwig and Schafer, Sebastian and Schueler, Beth and Silver, Mike and Timmer, Jan and Trousset, Yves and Zhang, Jie},
title = {AAPM Task Group Report 238: 3D C‐arms with volumetric imaging capability*},
journal = {Medical Physics},
year = {2023},
volume = {50},
number = {8},
doi = {10.1002/mp.16245}
}
EUVIMED