EUVIMEDEUVIMED entdecken
Crossref

Thickness Measurement of Quartz and Analysis of Interface Roughness Effects Based on Terahertz Time‐Domain Spectroscopy

Wenhui Yan, Hao Guan, Baiqiang Sun, Zhenwei Zhang

Microwave and Optical Technology Letters · 2026-07 · 68 (7)

DOI: 10.1002/mop.70691 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microwave and Optical Technology Letters, online erschienen am 06.07.2026. Verfasst von Wenhui Yan und 3 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pulsed terahertz signal technology is increasingly being applied across various industries as an effective means of measuring material thickness. In terahertz time‐domain spectroscopy systems, the presence of mixed noise affects the extraction of valid information and signal quality, making noise reduction essential for accurate thickness detection. Firstly, the system echoes are removed using double Gaussian inverse filtering, and then the system noise is removed using an adaptive variational mode decomposition method, which utilizes the minimum envelope entropy as the criterion, and through the sparrow search algorithm automatically optimizes the mode number and penalty factor to achieve adaptive and self‐consistent noise removal. The terahertz signals of parallel‐surface quartz specimens are reconstructed, and an automatic peak extraction algorithm is demonstrated. The influence of different surface roughness on reflective terahertz pulse signals and the correction parameters is quantitatively analyzed to achieve high‐precision automated thickness detection.

Zitieren

APA

Yan, W., Guan, H., Sun, B., & Zhang, Z. (2026). Thickness Measurement of Quartz and Analysis of Interface Roughness Effects Based on Terahertz Time‐Domain Spectroscopy. Microwave and Optical Technology Letters, 68(7). https://doi.org/10.1002/mop.70691

Vancouver

Yan W, Guan H, Sun B, Zhang Z. Thickness Measurement of Quartz and Analysis of Interface Roughness Effects Based on Terahertz Time‐Domain Spectroscopy. Microwave and Optical Technology Letters. 2026;68(7). doi:10.1002/mop.70691

BibTeX
@article{Yan2026,
  author = {Yan, Wenhui and Guan, Hao and Sun, Baiqiang and Zhang, Zhenwei},
  title = {Thickness Measurement of Quartz and Analysis of Interface Roughness Effects Based on Terahertz Time‐Domain Spectroscopy},
  journal = {Microwave and Optical Technology Letters},
  year = {2026},
  volume = {68},
  number = {7},
  doi = {10.1002/mop.70691}
}
Kostenlos starten →