Speed vs Accuracy: Effect on Ligand Pose Accuracy of Varying Box Size and Exhaustiveness in AutoDock Vina
Molecular Informatics · 2023-02 · 42 (2)
DOI: 10.1002/minf.202200188 ↗Kurz gefasst
Fachartikel in der Zeitschrift Molecular Informatics, online erschienen am 11.11.2022. Verfasst von Rupesh Agarwal und 1 weiteren Autor:innen. Beteiligte Einrichtung: UT/ORNL Center for Molecular Biophysics, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6309, USA. Hauptthemen laut MEDLINE: Software, Proteins. Die Arbeit wurde bisher 101-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: Office of Science.
Abstract (Originalsprache)
Structure‐based virtual high‐throughput screening involves docking chemical libraries to targets of interest. A parameter pertinent to the accuracy of the resulting pose is the root mean square deviation (RMSD) from a known crystallographic structure, i. e., the ‘docking power’. Here, using a popular algorithm, Autodock Vina, as a model program, we evaluate the effects of varying two common docking parameters: the box size (the size of docking search space) and the exhaustiveness of the global search (the number of independent runs starting from random ligand conformations) on the RMSD from the PDBbind v2017 refined dataset of experimental protein‐ligand complexes. Although it is clear that exhaustiveness is an important parameter, there is wide variation in the values used, with variation between 1 and >100. We, therefore, evaluated a combination of cubic boxes of different sizes and five exhaustiveness values (1, 8, 25, 50, 75, 100) within the range of those commonly adopted. The results show that the default exhaustiveness value of 8 performs well overall for most box sizes. In contrast, for all box sizes, but particularly for large boxes, an exhaustiveness value of 1 led to significantly higher median RMSD (mRMSD) values. The docking power was slightly improved with an exhaustiveness of 25, but the mRMSD changes little with values higher than 25. Therefore, although low exhaustiveness is computationally faster, the results are more likely to be far from reality, and, conversely, values >25 led to little improvement at the expense of computational resources. Overall, we recommend users to use at least the default exhaustiveness value of 8 for virtual screening calculations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- UT/ORNL Center for Molecular Biophysics, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6309, USA.
- Department of Biochemistry and Cellular and Molecular Biology, University of Tennessee, Knoxville, 14311 Cumberland Avenue, Knoxville, TN 37996-1939, USA.
ORCID-Profile: Rupesh Agarwal
Förderung
- Office of Science
Zitieren
APA
Agarwal, R., & Smith, J. C. (2023). Speed vs Accuracy: Effect on Ligand Pose Accuracy of Varying Box Size and Exhaustiveness in AutoDock Vina. Molecular Informatics, 42(2). https://doi.org/10.1002/minf.202200188
Vancouver
Agarwal R, Smith JC. Speed vs Accuracy: Effect on Ligand Pose Accuracy of Varying Box Size and Exhaustiveness in AutoDock Vina. Molecular Informatics. 2023;42(2). doi:10.1002/minf.202200188
BibTeX
@article{Agarwal2023,
author = {Agarwal, Rupesh and Smith, Jeremy C},
title = {Speed vs Accuracy: Effect on Ligand Pose Accuracy of Varying Box Size and Exhaustiveness in AutoDock Vina},
journal = {Molecular Informatics},
year = {2023},
volume = {42},
number = {2},
doi = {10.1002/minf.202200188}
}
EUVIMED