EUVIMEDEUVIMED entdecken
Fallbericht

Reconstruction of finger contracture with an expanded first dorsal metacarpal artery perforator flap: A case report

Burak Özkan iD, Burak Ergün Tatar iD, Süleyman Savran iD, Abbas Albayati iD, Cagri Ahmet Uysal iD

Microsurgery · 2024-01 · 44 (1)

DOI: 10.1002/micr.31057 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Microsurgery, online erschienen am 18.05.2023. Verfasst von Burak Özkan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic, Reconstructive and Aesthetic Surgery, Baskent University, Ankara, Turkey. Hauptthemen laut MEDLINE: Perforator Flap, Burns, Electric, Metacarpal Bones, Contracture. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 12 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Volar finger contractures can be challenging for plastic surgeons. The dorsal metacarpal artery perforator (DMCAP) flap is frequently used to cover bones, tendons, and neurovascular structures in the dorsum of the hand after trauma and burns as an alternative to grafts and free flaps. We aimed to report volar finger defect reconstruction with expanded DMCAP flap. A 9‐year‐old male patient applied to our clinic with the complaint of inability to open the second finger of the left hand after an electrical burn that caused proximal and distal interphalangeal joints flexion contractures. Reconstruction was planned for the patient with a two‐session expanded first DMCAP flap. A 16 mL 5 × 3 cm tissue expander was placed in the prepared area from the vertical incision in the first session. The tissue expander was inflated with 4 mL of isotonic solution. The DMCA area was enlarged 6 weeks later by giving 22 mL of isotonic solution. After the pedicle dissection, the 9 × 3 cm DMCAP flap was elevated by dissection over the paratenon. With 180° of rotation, the left‐hand second finger was adapted to the 6 × 2 cm defect area on the volar face. The flap donor site was closed primarily. The operation was terminated by placing the hand on a protective splint. There were no complications in the flap in the postoperative 6 months. The patient was referred to the physical therapy and rehabilitation department. As a result, an expanded DMCAP flap may cover volar tissue defects up to the distal phalanx. This report may present the first case in which volar finger contracture reconstruction was performed with an expanded first DMCAP flap after an electrical burn in a pediatric patient.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Perforator FlapBurns, ElectricMetacarpal BonesContractureFinger InjuriesSoft Tissue InjuriesMaleHumansChildTreatment OutcomeFingersArteriesIsotonic SolutionsSkin Transplantation

Substanzen

Isotonic Solutions

Autor:innen und Institutionen

  • Department of Plastic, Reconstructive and Aesthetic Surgery, Baskent University, Ankara, Turkey.
  • Department of Plastic, Reconstructive and Aesthetic Surgery, Erzurum Regional Training and Research Hospital, Erzurum, Turkey.

ORCID-Profile: Burak Özkan, Burak Ergün Tatar, Süleyman Savran, Abbas Albayati, Cagri Ahmet Uysal

Zitieren

APA

Özkan, B., Tatar, B. E., Savran, S., Albayati, A., & Uysal, C. A. (2024). Reconstruction of finger contracture with an expanded first dorsal metacarpal artery perforator flap: A case report. Microsurgery, 44(1). https://doi.org/10.1002/micr.31057

Vancouver

Özkan B, Tatar BE, Savran S, Albayati A, Uysal CA. Reconstruction of finger contracture with an expanded first dorsal metacarpal artery perforator flap: A case report. Microsurgery. 2024;44(1). doi:10.1002/micr.31057

BibTeX
@article{zkan2024,
  author = {Özkan, Burak and Tatar, Burak Ergün and Savran, Süleyman and Albayati, Abbas and Uysal, Cagri Ahmet},
  title = {Reconstruction of finger contracture with an expanded first dorsal metacarpal artery perforator flap: A case report},
  journal = {Microsurgery},
  year = {2024},
  volume = {44},
  number = {1},
  doi = {10.1002/micr.31057}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche