EUVIMEDEUVIMED entdecken
Crossref

Biodegradable 3D porous zinc alloy scaffold for bone fracture fixation devices

M Bobby Kannan, Jonathon Chappell, Hadis Khakbaz, Mehdi Taherishargh, Thomas Fiedler

MEDICAL DEVICES & SENSORS · 2020-12 · 3 (6)

DOI: 10.1002/mds3.10108 ↗

Kurz gefasst

Fachartikel in der Zeitschrift MEDICAL DEVICES & SENSORS, online erschienen am 31.07.2020. Verfasst von M Bobby Kannan und 4 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 64 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, a three‐dimensional (3D) porous zinc alloy (Zn‐Al 4 ) scaffold was produced using counter‐gravity infiltration casting method and its in vitro degradation behaviour was evaluated using an electrochemical technique in simulated body fluid (SBF) for potential applications in bone fracture fixation devices. The porous zinc alloy exhibited porosity of ~60% with interconnected pores, and the pore size was 1–2 mm. The in vitro potentiodynamic polarization results showed that the degradation rate of the porous zinc alloy was 0.16 mm/year, which is ~15% higher than that of the non‐porous pure zinc metal (0.14 mm/year). Highly biocompatible calcium phosphate (CaP) was electrochemically deposited on the porous zinc alloy and its in vitro degradation behaviour was also studied. The micrographs of the CaP deposited porous zinc alloy revealed uniformly coverage of CaP particles on the outer surface of the alloy and partial deposition on the inside of the pores. The morphology of the deposited CaP particles was predominantly spherical‐shaped, but flake‐like particles were also evident on the inside of the pores. Interestingly, the degradation rate of the CaP deposited porous zinc alloy (0.5 mm/year) was three times higher than that of the porous zinc alloy. It can be hypothesized that the restricted SBF flow through the partially blocked pores by the CaP particles have locally raised the pH inside the pores and thus increased the degradation.

Zitieren

APA

Kannan, M. B., Chappell, J., Khakbaz, H., Taherishargh, M., & Fiedler, T. (2020). Biodegradable 3D porous zinc alloy scaffold for bone fracture fixation devices. MEDICAL DEVICES & SENSORS, 3(6). https://doi.org/10.1002/mds3.10108

Vancouver

Kannan MB, Chappell J, Khakbaz H, Taherishargh M, Fiedler T. Biodegradable 3D porous zinc alloy scaffold for bone fracture fixation devices. MEDICAL DEVICES & SENSORS. 2020;3(6). doi:10.1002/mds3.10108

BibTeX
@article{Kannan2020,
  author = {Kannan, M Bobby and Chappell, Jonathon and Khakbaz, Hadis and Taherishargh, Mehdi and Fiedler, Thomas},
  title = {Biodegradable 3D porous zinc alloy scaffold for bone fracture fixation devices},
  journal = {MEDICAL DEVICES & SENSORS},
  year = {2020},
  volume = {3},
  number = {6},
  doi = {10.1002/mds3.10108}
}
Kostenlos starten →