An Alternative Approach to the Finger‐Tapping Test in Parkinsonian Patients: Finger to Crease Instead of Finger to Tip
Movement Disorders Clinical Practice · 2025
DOI: 10.1002/mdc3.70415 ↗Kurz gefasst
Fachartikel in der Zeitschrift Movement Disorders Clinical Practice, 2025. Verfasst von Fahimeh H Akhoundi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Parkinson and Other Movement Disorders Center, Department of Neurosciences, University of California San Diego, San Diego, California, USA. Hauptthemen laut MEDLINE: Fingers, Parkinson Disease, Hypokinesia, Neurologic Examination. Die Arbeit nennt 12 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Neurologic examination is still the main source of data gathering for diagnosing and monitoring diseases. Items of neurologic examination need to be researched to assess their reliability, reproducibility, and correlation with various scales.
Objective
To evaluate the competence of finger to crease (F‐C) variation of the finger tapping test as opposed to the traditional method (F‐T) in detecting bradykinesia in Parkinson's disease patients and to evaluate the interrater reliability of the test.
Methods
We compared the two finger tapping variations in 42 Parkinson's disease patients. We examined our patients using the bradykinesia subscale of the Unified Parkinson's Disease Rating Scale (UPDRS) and the Hoehn and Yahr (H&Y) scales with the two methods of the finger‐tapping test. To assess the interrater reliability of the test, a different pool of patients was used, in which four movement disorder specialists evaluated videos of 29 patients performing the finger‐tapping test using the two methods with each hand.
Results
Both methods were positively correlated with Parkinson staging based on the H&Y scale and the bradykinesia subsection of the UPDRS. Mean H&Y scores and UPDRS bradykinesia subscale scores given to the patients using the F‐C method were significantly higher than those when the F‐T method was employed. Using F‐C instead of F‐T led to a higher H&Y stage placement in 12 subjects. Both methods showed good to excellent inter‐rater reliability (Cronbach's alpha >0.80).
Conclusion
Our findings show that this finger‐tapping variation is reliable and may increase the sensitivity of the examination.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Parkinson and Other Movement Disorders Center, Department of Neurosciences, University of California San Diego, San Diego, California, USA.
- Department of Neurology, Cedars-Sinai Medical Center and David Geffen School of Medicine at University of California Los Angeles, Los Angeles, California, USA.
- Lou Ruvo Center for Brain Health, Cleveland Clinic, Cleveland, Ohio, USA.
- Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA.
- Department of Neurology, Cleveland Clinic, Cleveland, Ohio, USA.
ORCID-Profile: Irene Litvan
Zitieren
APA
Akhoundi, F. H., Bordelon, Y., Leverenz, J., Oikonomou, P., & Litvan, I. (2025). An Alternative Approach to the Finger‐Tapping Test in Parkinsonian Patients: Finger to Crease Instead of Finger to Tip. Movement Disorders Clinical Practice. https://doi.org/10.1002/mdc3.70415
Vancouver
Akhoundi FH, Bordelon Y, Leverenz J, Oikonomou P, Litvan I. An Alternative Approach to the Finger‐Tapping Test in Parkinsonian Patients: Finger to Crease Instead of Finger to Tip. Movement Disorders Clinical Practice. 2025. doi:10.1002/mdc3.70415
BibTeX
@article{Akhoundi2025,
author = {Akhoundi, Fahimeh H and Bordelon, Yvette and Leverenz, James and Oikonomou, Panteleimon and Litvan, Irene},
title = {An Alternative Approach to the Finger‐Tapping Test in Parkinsonian Patients: Finger to Crease Instead of Finger to Tip},
journal = {Movement Disorders Clinical Practice},
year = {2025},
doi = {10.1002/mdc3.70415}
}
EUVIMED