Cold EI—The Way to Improve GC‐MS and Increase Its Range of Applications
Mass Spectrometry Reviews · 2026-05 · 45 (3) · 548-582
DOI: 10.1002/mas.21928 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Mass Spectrometry Reviews, online erschienen am 05.03.2025. Verfasst von Aviv Amirav und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry, Tel Aviv University, Tel Aviv, Israel. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 116 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: This research was supported by the Israel Science Foundation (grant No 312/22)., Israel Science Foundation.
Abstract (Originalsprache)
Gas chromatography‐mass spectrometry (GC‐MS) with Cold electron ionization (EI) is based on interfacing the GC and MS with a supersonic molecular beam (SMB) along with electron ionization of vibrationally cold sample compounds in the SMB in a contact‐free fly‐through ion source (hence the name Cold EI). Cold EI improves all the central performance aspects of GC‐MS, including: a significantly extended range of compounds that are amenable for analysis, enhanced molecular ions, highly improved sample identification, faster analysis (much faster), uniform response to all analytes, greater selectivity and higher signal to noise ratios and lower limits of detection, particularly for compounds that are difficult to analyze. GC‐MS with Cold EI executes the analysis of the full range of standard EI applications and most with major improvements of various metrics. Furthermore, it significantly extends the range of compounds and applications amenable for GC‐MS analysis. Accordingly, it is a highly superior replacement ion source. In this review article, we describe Cold EI and its main features, discuss its benefits, and demonstrate several of its unique applications including cannabinoids analysis, synthetic organic compounds analysis, whole blood analysis for medical diagnostics, isomer distribution analysis for improved fuels and oils, and explosives analysis.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Chemistry, Tel Aviv University, Tel Aviv, Israel.
- Aviv Analytical Ltd, Hod Hasharon, Israel.
Förderung
- This research was supported by the Israel Science Foundation (grant No 312/22).
- Israel Science Foundation
Zitieren
APA
Amirav, A., Neumark, B., Elkabets, O., & Yakovchuk, A. (2026). Cold EI—The Way to Improve GC‐MS and Increase Its Range of Applications. Mass Spectrometry Reviews, 45(3), 548-582. https://doi.org/10.1002/mas.21928
Vancouver
Amirav A, Neumark B, Elkabets O, Yakovchuk A. Cold EI—The Way to Improve GC‐MS and Increase Its Range of Applications. Mass Spectrometry Reviews. 2026;45(3):548-582. doi:10.1002/mas.21928
BibTeX
@article{Amirav2026,
author = {Amirav, Aviv and Neumark, Benny and Elkabets, Oneg and Yakovchuk, Alex},
title = {Cold EI—The Way to Improve GC‐MS and Increase Its Range of Applications},
journal = {Mass Spectrometry Reviews},
year = {2026},
volume = {45},
number = {3},
pages = {548--582},
doi = {10.1002/mas.21928}
}
EUVIMED