EUVIMEDEUVIMED entdecken
Crossref

Pyrene‐Based “Turn‐On” Fluorescent Polymeric Probe with Thioacetal Units in the Main Chain for Mercury(II) Detection in Aqueous Solutions and Living Cells

Yu Gu iD, Siyong Li iD, Yue Yu iD, Jianjian Zhu iD, Xingyu Yuan iD, Xinxin Feng iD, Yanbing Lu iD

Macromolecular Rapid Communications · 2024

DOI: 10.1002/marc.202300631 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Macromolecular Rapid Communications, 2024. Verfasst von Yu Gu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Advanced Catalytic Engineering Research Center of the Ministry of Education, College of Chemistry and Chemical Engineering, Hunan University, Changsh…. Hauptthemen laut MEDLINE: Mercury. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 53 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A water‐soluble polymeric pyrene‐based polythioacetal (PTA‐Py) with thioacetal units in the main chain is simply synthesized by direct polycondensation of 3, 6‐dioxa‐1, 8‐octanedithiol, 1‐pyrene formaldehyde, and mPEG2k‐SH. The probe PTA‐Py shows a good fluorescence response to Hg 2+ ions due to the Hg 2+ ‐promoted deprotection reaction of thioacetal groups to regenerate the original 1‐pyrene formaldehyde compound. After adding Hg 2+ to the PTA‐Py solution, the fluorescence intensity (FI) gradually increases with increasing concentrations of Hg 2+ . Compared with other metal ions, the probe exhibits high sensitivity, good selectivity, and rapid response to Hg 2+ . The low detection limits are 12.3 n m in ethanol‐PBS buffer and 13.3 n m in water, respectively. The results imply that the simply synthesized water‐soluble polymeric probe had potential applications in the rapid detection of Hg 2+ ions in aqueous solutions. Moreover, the polymeric PTA‐Py shows high sensitivity for CH 3 Hg + with detection limits of 26.5 n m in ethanol/PBS buffer. In addition, PTA‐Py can efficiently detect Hg 2+ ions in HeLa cells. The results demonstrate that a valuable method is developed for biocompatible polymeric sensors for Hg 2+ ions in biological and environmental samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MercuryHumansFluorescent DyesHeLa CellsWaterPyrenesPolymersIonsSpectrometry, FluorescenceEthanolFormaldehyde

Stichwörter der Autor:innen

amphiphilic block polymercell imagingdithioacetalfluorescence detectionmercury ions

Substanzen

MercuryFluorescent DyesWaterpyrenePyrenesPolymersIonsEthanolFormaldehyde

Autor:innen und Institutionen

  • Advanced Catalytic Engineering Research Center of the Ministry of Education, College of Chemistry and Chemical Engineering, Hunan University, Changsha, Changsha, 410082, P. R. China.
  • State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, Changsha, 410082, P. R. China.

ORCID-Profile: Yu Gu, Siyong Li, Yue Yu, Jianjian Zhu, Xingyu Yuan, Xinxin Feng, Yanbing Lu

Zitieren

APA

Gu, Y., Li, S., Yu, Y., Zhu, J., Yuan, X., Feng, X., & Lu, Y. (2024). Pyrene‐Based “Turn‐On” Fluorescent Polymeric Probe with Thioacetal Units in the Main Chain for Mercury(II) Detection in Aqueous Solutions and Living Cells. Macromolecular Rapid Communications. https://doi.org/10.1002/marc.202300631

Vancouver

Gu Y, Li S, Yu Y, Zhu J, Yuan X, Feng X, et al. Pyrene‐Based “Turn‐On” Fluorescent Polymeric Probe with Thioacetal Units in the Main Chain for Mercury(II) Detection in Aqueous Solutions and Living Cells. Macromolecular Rapid Communications. 2024. doi:10.1002/marc.202300631

BibTeX
@article{Gu2024,
  author = {Gu, Yu and Li, Siyong and Yu, Yue and Zhu, Jianjian and Yuan, Xingyu and Feng, Xinxin and Lu, Yanbing},
  title = {Pyrene‐Based “Turn‐On” Fluorescent Polymeric Probe with Thioacetal Units in the Main Chain for Mercury(II) Detection in Aqueous Solutions and Living Cells},
  journal = {Macromolecular Rapid Communications},
  year = {2024},
  doi = {10.1002/marc.202300631}
}
Kostenlos starten →