MoS 2 ‐Polyaniline Based Flexible Electrochemical Biosensor: Toward pH Monitoring in Human Sweat
Macromolecular Materials and Engineering · 2023-08 · 308 (8)
DOI: 10.1002/mame.202300007 ↗Kurz gefasst
Fachartikel in der Zeitschrift Macromolecular Materials and Engineering, online erschienen am 17.04.2023. Verfasst von Sudipta Choudhury und 4 weiteren Autor:innen. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 81 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Wearable pH sensors for sweat analysis have garnered significant scientific attention for the detection of early signs of many physiological diseases. In this study, a MoS 2 ‐polyaniline (PANI) modified screen‐printed carbon electrode (SPCE) is fabricated and used as a sweat biosensor. The exfoliated MoS 2 nanosheets are drop casted over an SPCE and are functionalized by a conducting polymer, polyaniline (PANI) via the electropolymerization technique. The as‐fabricated biosensor exhibits high super‐Nernstian sensitivity of −70.4 ± 1.7 mV pH −1 in the linear range of pH 4 to 8 of 0.1 m standard phosphate buffer solution (PBS), with outstanding reproducibility. The sensor exhibits excellent selectivity against the common sweat ions including Na + , Cl − , K + , and NH 4 + with tremendous long‐term stability over 180 min from pH 4 to 6. The enhanced active surface area and better electrical conductivity as a consequence of the synergistic effect between MoS 2 and PANI are correlated with the boosted performance of the as‐produced biosensor. The feasibility of the sensor is further examined using an artificial sweat specimen and the successful detection confirms the potential of the biosensor for a real‐time noninvasive, skin attachable, and flexible wearable pH sensor.
Zitieren
APA
Choudhury, S., Deepak, D., Bhattacharya, G., McLaughlign, J., & Roy, S. S. (2023). MoS 2 ‐Polyaniline Based Flexible Electrochemical Biosensor: Toward pH Monitoring in Human Sweat. Macromolecular Materials and Engineering, 308(8). https://doi.org/10.1002/mame.202300007
Vancouver
Choudhury S, Deepak D, Bhattacharya G, McLaughlign J, Roy SS. MoS 2 ‐Polyaniline Based Flexible Electrochemical Biosensor: Toward pH Monitoring in Human Sweat. Macromolecular Materials and Engineering. 2023;308(8). doi:10.1002/mame.202300007
BibTeX
@article{Choudhury2023,
author = {Choudhury, Sudipta and Deepak, Deepak and Bhattacharya, Gourav and McLaughlign, James and Roy, Susanta Sinha},
title = {MoS 2 ‐Polyaniline Based Flexible Electrochemical Biosensor: Toward pH Monitoring in Human Sweat},
journal = {Macromolecular Materials and Engineering},
year = {2023},
volume = {308},
number = {8},
doi = {10.1002/mame.202300007}
}
EUVIMED