EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access

Bonding Strength of Universal Adhesives to Laser‐Etched Deep and Superficial Dentin

Özge Ünlü, Jale Görücü

Lasers in Surgery and Medicine · 2026-08 · 58 (6) · 490-498

DOI: 10.1002/lsm.70141 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Lasers in Surgery and Medicine, online erschienen am 28.04.2026. Verfasst von Özge Ünlü und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Restorative Dentistry, Lokman Hekim University, Ankara, Turkey. Hauptthemen laut MEDLINE: Dental Bonding, Dental Etching, Dentin, Dentin-Bonding Agents. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The effectiveness of laser‐etching (LE) on dentin shear bond strength (SBS) of universal adhesives remains unclear. This study aimed to compare the SBS of a nanohybrid composite resin to superficial and deep dentin following application of a contemporary universal adhesive using either self‐etch (SE) or LE. Materials and Methods Forty‐four extracted human molars were embedded in acrylic blocks and prepared to obtain superficial or deep dentin surfaces ( n = 22 each), and then assigned to four groups ( n = 11). The Scotchbond Universal Adhesive (SBU) was applied in SE in Groups 1 and 3, while dentin surfaces were conditioned with an Er, Cr:YSGG laser (1.5 W, 20 Hz) before adhesive application in Groups 2 and 4. The nanohybrid composite (Filtek Z550—FZU) was placed and light‐cured. SBS was determined with a universal testing machine, while fracture patterns were evaluated under a stereomicroscope, and the results were statistically assessed by either ANOVA or the Kruskal–Wallis test ( p < 0.05).

Results

Application of universal adhesive using SE and LE did not affect the shear bond strength of nanohybrid composite resin placed after application to superficial and deep dentin ( p > 0.05). Evaluation of failure types revealed no difference in failure type distribution between SE and LE groups ( p > 0.05).

Conclusion

Dentin depth and etching technique had no effect on the SBS of composite resin. No difference was found between groups in terms of failure types.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental BondingDental EtchingDentinDentin-Bonding AgentsLasers, Solid-StateHumansMolarShear StrengthMaterials TestingResin CementsComposite Resins

Stichwörter der Autor:innen

Er,Cr:YSGG laserdentinlaser‐etchself‐etchshear bond strengthuniversal adhesive

Substanzen

Dentin-Bonding AgentsScotchbondResin CementsFiltek Z550Composite Resins

Autor:innen und Institutionen

  • Department of Restorative Dentistry, Lokman Hekim University, Ankara, Turkey.

Zitieren

APA

Ünlü, Ö., & Görücü, J. (2026). Bonding Strength of Universal Adhesives to Laser‐Etched Deep and Superficial Dentin. Lasers in Surgery and Medicine, 58(6), 490-498. https://doi.org/10.1002/lsm.70141

Vancouver

Ünlü Ö, Görücü J. Bonding Strength of Universal Adhesives to Laser‐Etched Deep and Superficial Dentin. Lasers in Surgery and Medicine. 2026;58(6):490-498. doi:10.1002/lsm.70141

BibTeX
@article{nl2026,
  author = {Ünlü, Özge and Görücü, Jale},
  title = {Bonding Strength of Universal Adhesives to Laser‐Etched Deep and Superficial Dentin},
  journal = {Lasers in Surgery and Medicine},
  year = {2026},
  volume = {58},
  number = {6},
  pages = {490--498},
  doi = {10.1002/lsm.70141}
}
Kostenlos starten →