Comparative Efficacy and Safety of 1064‐nm Picosecond Laser and 1927‐nm Fractional Thulium Laser for Atrophic Acne Scars in Asian Patients: A Prospective, Randomized, Split‐Face Study
Lasers in Surgery and Medicine · 2026-08 · 58 (6) · 447-454
DOI: 10.1002/lsm.70134 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Lasers in Surgery and Medicine, online erschienen am 15.04.2026. Verfasst von Kai Jia und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dermatology, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China. Hauptthemen laut MEDLINE: Cicatrix, Lasers, Solid-State, Acne Vulgaris, Low-Level Light Therapy. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Natural Science Foundation of China, Xi'an Science and Technology Plan Project, Xi'an Jiaotong University Medical Development Fund.
Abstract (Originalsprache)
Background
Atrophic acne scars are a common sequela of inflammatory acne, resulting from abnormal dermal remodeling due to imbalance in collagen synthesis and degradation. Laser therapies, including picosecond and fractional lasers, have emerged as effective treatments, yet direct comparative studies remain limited.
Objective
To compare the efficacy, safety, and tolerability of 1064‐nm microlens array picosecond laser (P‐MLA) versus 1927‐nm sub‐ablative fractional thulium laser (FTL) in Asian patients with atrophic acne scars.
Methods
This prospective, single‐center, evaluator‐blinded, randomized trial employed a split‐face design. Thirty‐five patients with symmetric facial atrophic acne scars received three sessions of P‐MLA on one side and FTL on the contralateral side at 4‐week intervals. Clinical outcomes were assessed using ECCA scores and blinded physician GAIS. Objective skin parameters (TEWL, MI, and EI) were measured, and patient satisfaction and adverse events were recorded.
Results
Both lasers significantly improved ECCA scores compared to baseline (P‐MLA: 102.86 ± 47.47 → 86.86 ± 47.42, p < 0.001; FTL: 101.43 ± 44.89 → 85.57 ± 50.54, p < 0.001), with no significant difference between sides. GAIS score was significantly higher on the P‐MLA side (2.83 ± 1.272 vs. 2.57 ± 1.243, p = 0.037). P‐MLA demonstrated lower MI and EI at 3 months post‐treatment, reduced intraoperative pain, shorter crusting duration, and minimal social downtime, whereas FTL exhibited higher crusting and erythema. TEWL returned to baseline for both groups. Patient satisfaction was high and comparable between sides.
Conclusion
Both P‐MLA and FTL are effective for treating atrophic acne scars in Asian patients, demonstrating comparable clinical efficacy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Dermatology, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.
- Department of Dermatology, Aesthetic Medicine, Xi'an Honghui Hospital, Xi'an, China.
ORCID-Profile: Luyue Zhang, Dan Ye, Yu Zhu, Zhao Wang, Weihui Zeng
Förderung
- National Natural Science Foundation of China
- Xi'an Science and Technology Plan Project
- Xi'an Jiaotong University Medical Development Fund
Zitieren
APA
Jia, K., Zhang, L., Ye, D., Zhu, Y., Huang, S., Zhang, Q., Wang, Z., & Zeng, W. (2026). Comparative Efficacy and Safety of 1064‐nm Picosecond Laser and 1927‐nm Fractional Thulium Laser for Atrophic Acne Scars in Asian Patients: A Prospective, Randomized, Split‐Face Study. Lasers in Surgery and Medicine, 58(6), 447-454. https://doi.org/10.1002/lsm.70134
Vancouver
Jia K, Zhang L, Ye D, Zhu Y, Huang S, Zhang Q, et al. Comparative Efficacy and Safety of 1064‐nm Picosecond Laser and 1927‐nm Fractional Thulium Laser for Atrophic Acne Scars in Asian Patients: A Prospective, Randomized, Split‐Face Study. Lasers in Surgery and Medicine. 2026;58(6):447-454. doi:10.1002/lsm.70134
BibTeX
@article{Jia2026,
author = {Jia, Kai and Zhang, Luyue and Ye, Dan and Zhu, Yu and Huang, Shiliu and Zhang, Qiaoyun and Wang, Zhao and Zeng, Weihui},
title = {Comparative Efficacy and Safety of 1064‐nm Picosecond Laser and 1927‐nm Fractional Thulium Laser for Atrophic Acne Scars in Asian Patients: A Prospective, Randomized, Split‐Face Study},
journal = {Lasers in Surgery and Medicine},
year = {2026},
volume = {58},
number = {6},
pages = {447--454},
doi = {10.1002/lsm.70134}
}
EUVIMED