EUVIMEDEUVIMED entdecken
Crossref

Optical coherence tomography for in vivo longitudinal monitoring of artificial dermal scaffold

Ziye Chen iD, Qiong Cheng, Lingyun Wang iD, Yunfeng Mo, Ke Li, Jianhua Mo

Lasers in Surgery and Medicine · 2023-03 · 55 (3) · 316-326

DOI: 10.1002/lsm.23645 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Lasers in Surgery and Medicine, online erschienen am 19.02.2023. Verfasst von Ziye Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronic Information, Engineering School of Electronics and Information Engineering, Soochow University, Suzhou, China. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Skin. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 66 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Artificial dermal scaffold (ADS) has undergone rapid development and been increasingly used for treating skin wound in clinics due to its good biocompatibility, controllable degradation, and low risk of disease infection. To obtain good treatment efficacy, ADS needs to be monitored longitudinally during the treatment process. For example, scaffold‐tissue fit, cell in‐growth, vascular regeneration, and scaffold degradation are the key properties to be inspected. However, to date, there are no effective, real‐time, and noninvasive techniques to meet the requirement of the scaffold monitoring above. Materials and Methods In this study, we propose to use optical coherence tomography (OCT) to monitor ADS in vivo through three‐dimensional imaging. A swept source OCT system with a handheld probe was developed for in vivo skin imaging. Moreover, a cell in‐growth, vascular regeneration, and scaffold degradation rate (IRDR) was defined with the volume reduction rate of the scaffold's collagen sponge layer. To measure the IRDR, a semiautomatic image segmentation algorithm was designed based on U‐Net to segment the collagen sponge layer of the scaffold from OCT images.

Results

The results show that the scaffold‐tissue fit can be clearly visualized under OCT imaging. The IRDR can be computed based on the volume of the segmented collagen sponge layer. It is observed that the IRDR appeared to a linear function of the time and in addition, the IRDR varied among different skin parts.

Conclusion

Overall, it can be concluded that OCT has a good potential to monitor ADS in vivo. This can help guide the clinicians to control the treatment with ADS to improve the therapy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Optical CoherenceSkinCollagenImaging, Three-Dimensional

Stichwörter der Autor:innen

artificial dermal scaffoldimage segmentationlongitudinal motoringoptical coherence tomography

Substanzen

Collagen

Autor:innen und Institutionen

  • Department of Electronic Information, Engineering School of Electronics and Information Engineering, Soochow University, Suzhou, China.
  • Department of Burn and Plastic Surgery, The First Affiliated Hospital of Soochow University, Suzhou, China.

ORCID-Profile: Ziye Chen, Lingyun Wang

Zitieren

APA

Chen, Z., Cheng, Q., Wang, L., Mo, Y., Li, K., & Mo, J. (2023). Optical coherence tomography for in vivo longitudinal monitoring of artificial dermal scaffold. Lasers in Surgery and Medicine, 55(3), 316-326. https://doi.org/10.1002/lsm.23645

Vancouver

Chen Z, Cheng Q, Wang L, Mo Y, Li K, Mo J. Optical coherence tomography for in vivo longitudinal monitoring of artificial dermal scaffold. Lasers in Surgery and Medicine. 2023;55(3):316-326. doi:10.1002/lsm.23645

BibTeX
@article{Chen2023,
  author = {Chen, Ziye and Cheng, Qiong and Wang, Lingyun and Mo, Yunfeng and Li, Ke and Mo, Jianhua},
  title = {Optical coherence tomography for in vivo longitudinal monitoring of artificial dermal scaffold},
  journal = {Lasers in Surgery and Medicine},
  year = {2023},
  volume = {55},
  number = {3},
  pages = {316--326},
  doi = {10.1002/lsm.23645}
}
Kostenlos starten →