EUVIMEDEUVIMED entdecken
Crossref

Dual Response of a Perovskite Scintillator for Low‑Dose X‑Ray Imaging Detection and Beam Monitoring in Proton Radiotherapy

Zhongying Ma, Tianyuan Dai, Junchi Ma, Yingze Fu, Jyh‐Cheng Chen, Jian Zhu, Jianfeng Qiu

Laser & Photonics Reviews · 21.07.2026

DOI: 10.1002/lpor.71613 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Laser & Photonics Reviews, online erschienen am 21.07.2026. Verfasst von Zhongying Ma und 6 weiteren Autor:innen. Die Arbeit nennt 79 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The development of novel high‐performance radiation detectors is crucial for medical applications, particularly in X‐ray diagnostics and proton radiotherapy. Herein, we report a low‐cost perovskite single‐crystal scintillator as a versatile and scalable candidate for the detection of both x‐rays and high‐energy proton beams. Theas‐prepared Cs 3 Cu 2 I 5 : 20%Mn scintillator exhibits outstanding response characteristics across the energy ranges relevant to X‐ray medical imaging (50–150 keV) and proton therapy (70–220 MeV). It achieves a high light yield of 55 260 photons/MeV, and its response signals show excellent linearity with respect to both x‐ray dose and proton flux. Moreover, it exhibits a sensitive dynamic response to proton beams with different energies, achieving a minimum detection limit of 1.34 × 10 4 p/s. Reliability and environmental stability tests further confirm its potential for long‐term application in proton beam detection. Furthermore, a flexible film based on this scintillator enables real‐time, high‐definition visualization of proton beam spots and realizes dynamic beam tracking, verifying its capability for real‐time proton beam monitoring. This work highlights the great potential of Mn 2+ ‐doped Cs 3 Cu 2 I 5 as a favorable‐performance, wide‐range, and low‐cost material for medical radiation detection and provides new experimental insights for advancing perovskite‐based detectors in clinical proton therapy and radiography.

Zitieren

APA

Ma, Z., Dai, T., Ma, J., Fu, Y., Chen, J., Zhu, J., & Qiu, J. (2026). Dual Response of a Perovskite Scintillator for Low‑Dose X‑Ray Imaging Detection and Beam Monitoring in Proton Radiotherapy. Laser & Photonics Reviews. https://doi.org/10.1002/lpor.71613

Vancouver

Ma Z, Dai T, Ma J, Fu Y, Chen J, Zhu J, et al. Dual Response of a Perovskite Scintillator for Low‑Dose X‑Ray Imaging Detection and Beam Monitoring in Proton Radiotherapy. Laser & Photonics Reviews. 2026. doi:10.1002/lpor.71613

BibTeX
@article{Ma2026,
  author = {Ma, Zhongying and Dai, Tianyuan and Ma, Junchi and Fu, Yingze and Chen, Jyh‐Cheng and Zhu, Jian and Qiu, Jianfeng},
  title = {Dual Response of a Perovskite Scintillator for Low‑Dose X‑Ray Imaging Detection and Beam Monitoring in Proton Radiotherapy},
  journal = {Laser & Photonics Reviews},
  year = {2026},
  doi = {10.1002/lpor.71613}
}
Kostenlos starten →