EUVIMEDEUVIMED entdecken
Crossref

Accuracy analysis of cholesterol analyzer in detecting dyslipidemia in truck drivers

Alessandra Aparecida Vieira Machado iD, Rosemeyre Vasconcelos Carvalho Cunha, Renato Bichat Pinto de Arruda, Tays Oliveira Silva, Julliete Cristina de Oliveira, Eunice Stella Jardim Cury, Antonio Sales, Stella Hissami Korin, Flavio Júnior Ferraz Cabral, Leonardo Roever, Antonio José Grande iD

Lipids · 2025

DOI: 10.1002/lipd.12427 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Lipids, 2025. Verfasst von Alessandra Aparecida Vieira Machado und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, State University of Mato Grosso do Sul (UEMS), Campo Grande, Mato Grosso do Sul, Brazil. Hauptthemen laut MEDLINE: Dyslipidemias, Cholesterol. Die Arbeit nennt 36 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cardiovascular diseases (CVD) are a leading cause of mortality and morbidity worldwide. Rapid diagnostic tools are crucial for timely intervention, especially in high‐risk groups such as truck drivers. In Brazil, the Mission® test uniquely offers test strips for simultaneous measurement of total cholesterol (TC), high‐density lipoprotein (HDL), triglycerides (TG), and low‐density lipoprotein (LDL). This study evaluates the accuracy of the Mission® analyzer compared to laboratory testing for HDL‐C, TG, and TC in truck drivers. A blinded cross‐sectional study was conducted among truck drivers aged 30–64 in Campo Grande, Mato Grosso do Sul, Brazil. Spearman correlation, linear regression, and the Bland–Altman analyses were employed to compare lipid profile results between the Mission® analyzer and laboratory methods. A total of 108 samples were analyzed. For HDL, the Mission® analyzer showed a sensitivity of 0.88, a specificity of 0.67, and an area under the curve (AUC) of 0.77 (95% CI: 0.68–0.86). For TG, sensitivity and specificity were 0.96 and 0.98, respectively, with an AUC of 0.97 (95% CI: 0.93–1.0). For TC, the AUC was 0.87 (95% CI: 0.79–0.95). Bland–Altman analysis revealed biases of −4.5 for HDL, 12.4 for TC, and −42.8 for TG between Mission® and laboratory results. The Mission® analyzer demonstrates good accuracy for rapid dyslipidemia diagnosis and Framingham Global Risk Score calculation. It is a valuable tool for initial screening and risk assessment, confirmation with laboratory testing is recommended for definitive diagnosis and treatment planning.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DyslipidemiasCholesterolHumansAdultMiddle AgedMaleTriglyceridesCross-Sectional StudiesBrazilCholesterol, HDLAutomobile DrivingTruck Drivers

Stichwörter der Autor:innen

bloodcholesterolhyperlipidemiaspoint‐of‐care testingtruck drivers

Substanzen

TriglyceridesCholesterolCholesterol, HDL

Autor:innen und Institutionen

  • Department of Medicine, State University of Mato Grosso do Sul (UEMS), Campo Grande, Mato Grosso do Sul, Brazil.
  • Department of Exact Sciences, UNIDERP - Anhanguera, Campo Grande, Mato Grosso do Sul, Brazil.
  • Department of Clinical Research, Brazilian Evidence-Based Health Network, Uberlândia, Minas Gerais, Brazil.
  • Gilbert and Rose-Marie Chagoury School of Medicine, Lebanese American University, Beirut, Lebanon.

ORCID-Profile: Alessandra Aparecida Vieira Machado, Antonio José Grande

Zitieren

APA

Machado, A. A. V., Cunha, R. V. C., de Arruda, R. B. P., Silva, T. O., de Oliveira, J. C., Cury, E. S. J., Sales, A., Korin, S. H., Ferraz Cabral, F. J., Roever, L., & Grande, A. J. (2025). Accuracy analysis of cholesterol analyzer in detecting dyslipidemia in truck drivers. Lipids. https://doi.org/10.1002/lipd.12427

Vancouver

Machado AAV, Cunha RVC, de Arruda RBP, Silva TO, de Oliveira JC, Cury ESJ, et al. Accuracy analysis of cholesterol analyzer in detecting dyslipidemia in truck drivers. Lipids. 2025. doi:10.1002/lipd.12427

BibTeX
@article{Machado2025,
  author = {Machado, Alessandra Aparecida Vieira and Cunha, Rosemeyre Vasconcelos Carvalho and de Arruda, Renato Bichat Pinto and Silva, Tays Oliveira and de Oliveira, Julliete Cristina and Cury, Eunice Stella Jardim and Sales, Antonio and Korin, Stella Hissami and Ferraz Cabral, Flavio Júnior and Roever, Leonardo and Grande, Antonio José},
  title = {Accuracy analysis of cholesterol analyzer in detecting dyslipidemia in truck drivers},
  journal = {Lipids},
  year = {2025},
  doi = {10.1002/lipd.12427}
}
Kostenlos starten →