Fachartikel in der Zeitschrift Laryngoscope Investigative Otolaryngology, online erschienen am 25.04.2026. Verfasst von Weibing Cai und 7 weiteren Autor:innen. Beteiligte Einrichtung: Morgan State University Baltimore Maryland USA. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIH HHS, National Institutes of Health, National Aeronautics and Space Administration.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate how subperichondrial mobilization affects implant‐tissue mechanics, glottal configuration, and vibratory behavior in computational simulations of medialization laryngoplasty (ML).

Methods

We used a finite‐discrete element method (FDEM) framework to simulate subperichondrial tissue‐cartilage separation and implant insertion in laryngeal models reconstructed from high‐resolution magnetic resonance imaging. Four dissection conditions were evaluated, ranging from no mobilization to increasing dissection length distal to the thyroplasty window. Outcome measures included change in glottal area, vocal fold medial displacement, finite element fracturing along the tissue‐cartilage interface, and estimated vibratory frequency.

Results

Increasing dissection length produced increased medial displacement, progressive reductions in glottal area, fewer secondary extensions of the dissection plane during implantation, and higher estimated vibratory frequencies (range: 100.4–120.8 Hz). These findings indicate that subperichondrial tissue mobilization alters implant‐induced force transmission and modifies boundary conditions relevant to vibration.

Conclusion

In this first application of FDEM to simulate laryngeal biomechanics in ML, subperichondrial dissection length demonstrated direct effects on model predictions relevant to implant sizing, placement strategy, and anticipated phonatory outcomes. Incorporating tissue mobilization into computational frameworks as a mechanically meaningful variable improves physiological realism and supports future development of subject‐specific surgical planning tools. Level of Evidence Level V. This study provides preclinical computational evidence using FDEM, supporting and extending clinical observations in ML.

Schlagwörter

Stichwörter der Autor:innen

biomechanical simulationfinite‐discrete element methodglottis physiologylaryngeal biomechanicslaryngeal cartilage surgerylaryngoplastytissue mobilizationvocal folds physiology

Autor:innen und Institutionen

  • Morgan State University Baltimore Maryland USA.
  • University of Pittsburgh Pittsburgh Pennsylvania USA.
  • University of Minnesota Minneapolis Minnesota USA.

ORCID-Profile: Stephanie Misono, Zheng Li

Förderung

  • NIH HHS
  • National Institutes of Health
  • National Aeronautics and Space Administration

Zitieren

APA

Cai, W., Wilson, A., He, G., Hary, E., Tkac, I., Misono, S., Sayce, L., & Li, Z. (2026). Comprehensive Numerical and Experimental Investigations on Endolaryngeal Mobilization. Laryngoscope Investigative Otolaryngology, 11(2). https://doi.org/10.1002/lio2.70419

Vancouver

Cai W, Wilson A, He G, Hary E, Tkac I, Misono S, et al. Comprehensive Numerical and Experimental Investigations on Endolaryngeal Mobilization. Laryngoscope Investigative Otolaryngology. 2026;11(2). doi:10.1002/lio2.70419

BibTeX
@article{Cai2026,
  author = {Cai, Weibing and Wilson, Azure and He, Guofeng and Hary, Elizabeth and Tkac, Ivan and Misono, Stephanie and Sayce, Lea and Li, Zheng},
  title = {Comprehensive Numerical and Experimental Investigations on Endolaryngeal Mobilization},
  journal = {Laryngoscope Investigative Otolaryngology},
  year = {2026},
  volume = {11},
  number = {2},
  doi = {10.1002/lio2.70419}
}
Kostenlos starten →