Fachartikel in der Zeitschrift The Laryngoscope, online erschienen am 21.08.2026. Verfasst von Koki Hasebe und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology, Head and Neck Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Terumo Life Science Foundation, SBC Medical Promotion Foundation, Suzuken Memorial Foundation, and JST SPRING.
Abstract (Originalsprache)
Objective
To test whether smartphone‐captured high‐resolution 3D facial geometry can objectively quantify the severity of facial nerve palsy (FNP).
Methods
We enrolled 99 patients with peripheral acute unilateral FNP (207 visits) and 12 healthy volunteers (July 2021–February 2024). The facial dynamics were captured using a smartphone with a 3D front‐facing camera, yielding a facial mesh comprising 1220 vertices. Recordings were obtained for multiple facial tasks. Clinical benchmarks included the House–Brackmann (HB) grading and electrophysiology. Features of displacement, velocity, acceleration, and asymmetry were extracted. Random forest regressors were trained for signed continuous HB (side‐aware) score prediction and for region‐specific prediction. Patient‐wise cross‐validation was used. Regressor performance was evaluated using Spearman's ρ , mean absolute error, R 2 , and area under the curve for HB ≥ III.
Results
The continuous HB regression model achieved a mean absolute error of 0.718, an R 2 of 0.851, and a Spearman's ρ of 0.935. Predictions for healthy controls were tightly clustered. The area under the receiver operating characteristic curve for screening for HB ≥ III was 0.914 ± 0.052. Region‐specific analyses showed the best performance for eyelid closure and teeth exposure. Regression using integrated electromyography demonstrated moderate correlations, while electroneurography showed weak correlations.
Conclusion
Smartphone‐captured high‐frame‐rate 3D facial geometry enabled accurate side‐aware continuous HB estimation and robust screening for clinically significant palsy. This method can detect subtle residual asymmetry beyond human grading, is robust for healthy controls, and may facilitate early detection, standardized monitoring, and at‐home rehabilitation of FNP. Level of Evidence 3.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otolaryngology, Head and Neck Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
- Department of Otolaryngology, Tenri Hospital, Nara, Japan.
- Department of Otolaryngology - Head and Neck Surgery, School of Medicine, University of Occupational and Environmental Health, Fukuoka, Japan.
- Department of Head and Neck Oncology and Innovative Treatment, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
ORCID-Profile: Koki Hasebe, Tsuyoshi Kojima, Shintaro Fujimura, Ryohei Yuki, Harukazu Hiraumi, Koichi Omori
Förderung
- Terumo Life Science Foundation, SBC Medical Promotion Foundation, Suzuken Memorial Foundation, and JST SPRING
Zitieren
APA
Hasebe, K., Kojima, T., Fujimura, S., Takata, K., Otsuki, S., Yuki, R., Okanoue, Y., Hiraumi, H., Hori, R., & Omori, K. (2026). Dynamic and Objective Quantification of Facial Nerve Palsy Using Smartphone‐Based 3D Facial Geometry. The Laryngoscope. https://doi.org/10.1002/lary.70827
Vancouver
Hasebe K, Kojima T, Fujimura S, Takata K, Otsuki S, Yuki R, et al. Dynamic and Objective Quantification of Facial Nerve Palsy Using Smartphone‐Based 3D Facial Geometry. The Laryngoscope. 2026. doi:10.1002/lary.70827
BibTeX
@article{Hasebe2026,
author = {Hasebe, Koki and Kojima, Tsuyoshi and Fujimura, Shintaro and Takata, Kuniaki and Otsuki, Shuya and Yuki, Ryohei and Okanoue, Yusuke and Hiraumi, Harukazu and Hori, Ryusuke and Omori, Koichi},
title = {Dynamic and Objective Quantification of Facial Nerve Palsy Using Smartphone‐Based 3D Facial Geometry},
journal = {The Laryngoscope},
year = {2026},
doi = {10.1002/lary.70827}
}
EUVIMED