Mechanical Characterization of Slide Tracheoplasty Versus End‐to‐End Anastomosis in Ex Vivo Porcine Tracheas
The Laryngoscope · 2026
DOI: 10.1002/lary.70673 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Laryngoscope, 2026. Verfasst von Travis Peng und 6 weiteren Autor:innen. Beteiligte Einrichtung: Northwell Health, New Hyde Park, New York, USA. Hauptthemen laut MEDLINE: Anastomosis, Surgical, Trachea, Plastic Surgery Procedures, Tracheal Stenosis. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Goody Two Shoes Foundation, Naiburg-Smith Family, The Berro Family Foundation.
Abstract (Originalsprache)
Background
Slide tracheoplasty and end‐to‐end anastomosis are two common reconstructive techniques for airway stenosis. While slide tracheoplasty is often preferred for its larger luminal diameter and reduced anastomotic tension, its mechanical integrity relative to end‐to‐end repair remains incompletely characterized. This study aimed to compare tensile strength and elastic properties between the two repair techniques in an ex vivo porcine model.
Methods
Porcine tracheas were harvested, bisected, and reattached using either end‐to‐end anastomosis or slide tracheoplasty. Tensile testing was performed to a maximum load of 45 N using a uniaxial testing system. Load at failure, stress–strain behavior, and Young's modulus were calculated. Survival analysis was performed using the log‐rank test to compare construct integrity between groups. Negative and positive pressure testing was performed.
Results
Seventy‐five percent of slide tracheoplasty samples failed under tension, with a median failure load of 32.96 N, whereas none (0%) of the end‐to‐end repairs failed within the 45 N test limit ( p = 0.0401). At equivalent strain, slide tracheoplasty constructs demonstrated lower stress compared with end‐to‐end anastomoses. Young's modulus was similarly reduced in the slide group.
Conclusion
Slide tracheoplasty constructs demonstrated lower tensile strength and stiffness than end‐to‐end repairs, suggesting that the redistribution of mechanical forces across a larger surface area reduces localized stress but limits overall load‐bearing capacity. This broader force dispersion may protect the anastomotic site from focal tension and dehiscence but results in susceptibility to elongation or deformation under chronic strain. These mechanical considerations are important for surgeons when selecting a repair technique and ensuring long‐term postoperative airway stability. Level of Evidence N/A.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Northwell Health, New Hyde Park, New York, USA.
- Orthopaedic Research Lab, Feinstein Institute for Medical Research, Manhasset, New York, USA.
- Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, 500 Hofstra University, Hempstead, New York, USA.
- Department of Biotechnology, Shoolini University, Solan, Himachal Pradesh, India.
- Center for Learning and Innovation, Northwell Health, Manhasset, New York, USA.
- Division of Pediatric Otolaryngology, Steven and Alexandra Cohen Children's Medical Center of New York, New Hyde Park, New York, USA.
ORCID-Profile: Pooja Swami
Förderung
- Goody Two Shoes Foundation
- Naiburg-Smith Family
- The Berro Family Foundation
Zitieren
APA
Peng, T., Swami, P., Goldstein, T., Neuwirth, A., Grande, D. A., Smith, L. P., & Scheffler, P. (2026). Mechanical Characterization of Slide Tracheoplasty Versus End‐to‐End Anastomosis in Ex Vivo Porcine Tracheas. The Laryngoscope. https://doi.org/10.1002/lary.70673
Vancouver
Peng T, Swami P, Goldstein T, Neuwirth A, Grande DA, Smith LP, et al. Mechanical Characterization of Slide Tracheoplasty Versus End‐to‐End Anastomosis in Ex Vivo Porcine Tracheas. The Laryngoscope. 2026. doi:10.1002/lary.70673
BibTeX
@article{Peng2026,
author = {Peng, Travis and Swami, Pooja and Goldstein, Todd and Neuwirth, Allison and Grande, Daniel A and Smith, Lee P and Scheffler, Patrick},
title = {Mechanical Characterization of Slide Tracheoplasty Versus End‐to‐End Anastomosis in Ex Vivo Porcine Tracheas},
journal = {The Laryngoscope},
year = {2026},
doi = {10.1002/lary.70673}
}
EUVIMED