EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Long‐Term Cochlear Implant Sensitivity in Patients With Far Advanced Otosclerosis

Raphaële Quatre iD, Åsa Bonnard, Jeremy Wales, Martin Eklöf

The Laryngoscope · 2025

DOI: 10.1002/lary.32271 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Laryngoscope, 2025. Verfasst von Raphaële Quatre und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oto-Rhino-Laryngology, Head and Neck Surgery, University Hospital, Grenoble Alpes, France. Hauptthemen laut MEDLINE: Otosclerosis, Cochlear Implants, Cochlear Implantation. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Cochlear implantation in otosclerosis patients presents unique surgical and programming challenges. The success and satisfaction of these patients heavily depend on precise speech processor fitting. Increased bone growth and tissue mass associated with otosclerosis can hinder electrical current flow, adding resistance to stimuli transmission to ganglion cells. This study aimed to evaluate mid‐ and long‐term cochlear implant fitting in otosclerosis patients compared to a control group.

Methods

This was a monocentric retrospective case–control study conducted at a tertiary referral center comparing patients with far advanced otosclerosis and a control group of post‐lingually deafened individuals from the same database. Data collected included: age, sex, etiology, hearing deprivation duration, implantation age and side, surgical details, postoperative complications (e.g., tinnitus, dizziness, or facial nerve stimulation), hearing tests, and cochlear implant fitting details.

Results

The study analyzed 80 patients: 29 with otosclerosis and 51 controls. Higher impedances were seen in the otosclerosis group at 2 and 5 years, statistically significant for basal, middle, and overall electrodes at 2 years. Higher C‐ and T‐levels for apical electrodes at 2 years were identified, and neural response telemetry thresholds were significantly higher for medial and apical electrodes in otosclerosis patients at 2 years. Despite these differences, auditory outcomes at 5 years were comparable between groups.

Conclusion

These findings suggest significant tissue remodeling at the cochlear apex in otosclerosis patients, likely increasing resistance to electrical currents delivered by the implant. This highlights the importance of tailored programming and long‐term monitoring for otosclerosis patients. Level of Evidence Level 3.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OtosclerosisCochlear ImplantsCochlear ImplantationHumansMaleFemaleRetrospective StudiesMiddle AgedCase-Control StudiesAdultAgedAuditory ThresholdTime Factors

Stichwörter der Autor:innen

cochlear implant fittingcochlear implantationfar advanced otosclerosishearing outcomes

Autor:innen und Institutionen

  • Department of Oto-Rhino-Laryngology, Head and Neck Surgery, University Hospital, Grenoble Alpes, France.
  • GeodAIsics, Grenoble, France.
  • BrainTech Lab INSERM UMR 2015, Grenoble, France.
  • Department of CLINTEC, Div of Otorhinolaryngology, Karolinska Institutet, Stockholm, Sweden.
  • Medical Unit of ENT, Hearing and Balance, Karolinska University Hospital, Stockholm, Sweden.

ORCID-Profile: Raphaële Quatre

Zitieren

APA

Quatre, R., Bonnard, Å., Wales, J., & Eklöf, M. (2025). Long‐Term Cochlear Implant Sensitivity in Patients With Far Advanced Otosclerosis. The Laryngoscope. https://doi.org/10.1002/lary.32271

Vancouver

Quatre R, Bonnard Å, Wales J, Eklöf M. Long‐Term Cochlear Implant Sensitivity in Patients With Far Advanced Otosclerosis. The Laryngoscope. 2025. doi:10.1002/lary.32271

BibTeX
@article{Quatre2025,
  author = {Quatre, Raphaële and Bonnard, Åsa and Wales, Jeremy and Eklöf, Martin},
  title = {Long‐Term Cochlear Implant Sensitivity in Patients With Far Advanced Otosclerosis},
  journal = {The Laryngoscope},
  year = {2025},
  doi = {10.1002/lary.32271}
}
Kostenlos starten →