EUVIMEDEUVIMED entdecken
Crossref

Evaluating the Effect of Various Pure Tone Averages on Cochlear Implant Candidacy Screening

Rachel C Greiner iD, Arun M Raghavan, Noga Lipschitz iD, Gavriel D Kohlberg

The Laryngoscope · 2025

DOI: 10.1002/lary.32018 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Laryngoscope, 2025. Verfasst von Rachel C Greiner und 3 weiteren Autor:innen. Beteiligte Einrichtung: University of Washington School of Medicine, Seattle, Washington, USA. Hauptthemen laut MEDLINE: Cochlear Implants, Audiometry, Pure-Tone, Cochlear Implantation, Patient Selection. Die Arbeit nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To provide evidence to use an extended frequency pure tone average to screen for cochlear implant evaluation candidates as recommended by the American Cochlear Implant Alliance. Additionally, to determine whether traditional low frequency, high or low frequency, high frequency, or extended frequency pure tone average most accurately predicts cochlear implant candidates based on speech perception scores from aided AzBio sentence testing or aided consonant‐nucleus‐consonant (CNC) testing.

Method

Adults from a tertiary care center who completed aided sentence testing during cochlear implant evaluation between 2014 and 2024 were assessed. Pure tone averages at low, high, low or high, and extended frequency ranges were evaluated with individual ear's aided AzBio or aided CNC scores as an outcome. Sensitivity, specificity, negative predictive value, and positive predictive value were assessed and compared using a paired study design.

Results

There were 675 observations from 363 patients with AzBio as an outcome variable and 665 observations from 364 patients with CNC scores as an outcome variable. High or low frequency achieved the highest sensitivity at 96.3% AzBio as an outcome and 95.6% with CNC as an outcome, which was significantly better than low frequency ( p < 0.001). Low frequency achieved the best specificity at 63.6% with AzBio as an outcome 76.9% with CNC as an outcome.

Conclusion

Extended frequency pure tones resulted in greater sensitivity in predicting CI candidates compared with the traditionally used low frequency pure tone average. Screening with wider frequency values will lead to a greater number of patients being identified for a cochlear implant evaluation. Level of Evidence 3 Laryngoscope , 135:2100–2106, 2025

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cochlear ImplantsAudiometry, Pure-ToneCochlear ImplantationPatient SelectionHumansMaleFemaleMiddle AgedAdultAgedSpeech PerceptionPredictive Value of TestsSensitivity and SpecificityRetrospective Studies

Stichwörter der Autor:innen

audiogramcochlear implantshearing loss

Autor:innen und Institutionen

  • University of Washington School of Medicine, Seattle, Washington, USA.
  • Department of Otolaryngology - Head and Neck Surgery, University of Washington, Seattle, Washington, USA.
  • Department of Otolaryngology - Head and Neck Surgery, Rabin Medical Center, Petah Tikva, Israel.

ORCID-Profile: Rachel C Greiner, Noga Lipschitz

Zitieren

APA

Greiner, R. C., Raghavan, A. M., Lipschitz, N., & Kohlberg, G. D. (2025). Evaluating the Effect of Various Pure Tone Averages on Cochlear Implant Candidacy Screening. The Laryngoscope. https://doi.org/10.1002/lary.32018

Vancouver

Greiner RC, Raghavan AM, Lipschitz N, Kohlberg GD. Evaluating the Effect of Various Pure Tone Averages on Cochlear Implant Candidacy Screening. The Laryngoscope. 2025. doi:10.1002/lary.32018

BibTeX
@article{Greiner2025,
  author = {Greiner, Rachel C and Raghavan, Arun M and Lipschitz, Noga and Kohlberg, Gavriel D},
  title = {Evaluating the Effect of Various Pure Tone Averages on Cochlear Implant Candidacy Screening},
  journal = {The Laryngoscope},
  year = {2025},
  doi = {10.1002/lary.32018}
}
Kostenlos starten →