Diagnostic Accuracy of Beta‐2 Transferrin Gel Electrophoresis for Detecting Cerebrospinal Fluid Rhinorrhea
The Laryngoscope · 14.10.2024
DOI: 10.1002/lary.31845 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Laryngoscope, online erschienen am 14.10.2024. Verfasst von Jacob G Eide und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology-Head and Neck Surgery, Henry Ford Health, Detroit, Michigan, U.S.A. Hauptthemen laut MEDLINE: Cerebrospinal Fluid Rhinorrhea, Transferrin, Sensitivity and Specificity. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 10 Literaturangaben.
Abstract (Originalsprache)
Objective
Unilateral thin clear rhinorrhea (UTCR) may represent a variety of pathologies including cerebrospinal fluid (CSF) rhinorrhea. Beta‐2 transferrin (B2Tf) gel electrophoresis (GE) has become the preferred testing modality due to reportedly high sensitivity (87%–100%) and specificity (71%–100%). However, there have been relatively few studies assessing its diagnostic accuracy. The purpose of this single‐institution study was to determine the accuracy of B2Tf GE in detecting CSF rhinorrhea.
Methods
A single‐center retrospective review was conducted from 2016 and 2024 for all patients who presented with UTCR and underwent B2Tf GE. Institutional review board approval was obtained. The gold standard for diagnostic confirmation of true and false positives (TP, FP) as well as false negatives (FN) was endoscopic exploration. The gold standard for true negative (TN) was response to medical therapy.
Results
A total of 105 patients underwent 149 B2Tf GE tests. 40 (38.1%) patients were diagnosed with CSF rhinorrhea. Of the 149 B2‐Tf GE tests, there were 51 TPs, 72 TNs, 20 FPs, and 6 FNs yielding 89.5% sensitivity, 78.3% specificity, 71.8% positive predictive value, and 92.3% negative predictive value, respectively. Of the false results the most common causes for error were purulent sinusitis ( n = 6, 23.1%), possible mucous contamination from nose‐blowing during collection ( n = 3, 11.5%), patient collection error ( n = 3, 11.5%), and blood contamination ( n = 1, 3.8%).
Conclusion
Although these single‐institutional data demonstrate test accuracy within ranges previously reported in the literature, they also demonstrate diagnostic limitations. Future studies should explore reasons for erroneous B2Tf GE results and how these may change clinical decision‐making. Level of Evidence IV Laryngoscope , 2024
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Otolaryngology-Head and Neck Surgery, Henry Ford Health, Detroit, Michigan, U.S.A.
- Department of Pathology, Henry Ford Health, Detroit, Michigan, U.S.A.
- Department of Neurosurgery, Henry Ford Health, Detroit, Michigan, U.S.A.
ORCID-Profile: Jacob G Eide, William Mason, Amrita Ray, John R Craig
Zitieren
APA
Eide, J. G., Mason, W., Mackie, H., Cook, B., Ray, A., Asmaro, K., Robin, A., Rock, J., & Craig, J. R. (2024). Diagnostic Accuracy of Beta‐2 Transferrin Gel Electrophoresis for Detecting Cerebrospinal Fluid Rhinorrhea. The Laryngoscope. https://doi.org/10.1002/lary.31845
Vancouver
Eide JG, Mason W, Mackie H, Cook B, Ray A, Asmaro K, et al. Diagnostic Accuracy of Beta‐2 Transferrin Gel Electrophoresis for Detecting Cerebrospinal Fluid Rhinorrhea. The Laryngoscope. 2024. doi:10.1002/lary.31845
BibTeX
@article{Eide2024,
author = {Eide, Jacob G and Mason, William and Mackie, Hussein and Cook, Bernard and Ray, Amrita and Asmaro, Karam and Robin, Adam and Rock, Jack and Craig, John R},
title = {Diagnostic Accuracy of Beta‐2 Transferrin Gel Electrophoresis for Detecting Cerebrospinal Fluid Rhinorrhea},
journal = {The Laryngoscope},
year = {2024},
doi = {10.1002/lary.31845}
}
EUVIMED