Pediatric Esophageal Button Battery Protocol Reduces Time From Presentation to Removal
The Laryngoscope · 2024
DOI: 10.1002/lary.31607 ↗Kurz gefasst
Studienprotokoll in der Zeitschrift The Laryngoscope, 2024. Verfasst von Samantha Goh und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology-Head and Neck Surgery, Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada. Hauptthemen laut MEDLINE: Esophagus, Foreign Bodies, Electric Power Supplies, Clinical Protocols. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 48 Literaturangaben.
Abstract (Originalsprache)
Objective
Evaluate implementation of an institutional protocol to reduce the time to removal of esophageal button battery (BB) and increase use of mitigation strategies.
Methods
We developed a protocol for esophageal BB management [Zakai's Protocol (ZP)]. All cases of esophageal BB impaction managed at a tertiary care center before and after implementation from 2011 to 2023 were reviewed. Time to BB removal, adherence to critical steps, and use of mitigation strategies (honey/sucralfate, acetic acid) were evaluated.
Results
Fifty‐one patients (38 pre‐ZP, 13 post‐ZP) were included. Median age was 2.3 years (IQR 1.3–3.4). After implementation, the time from arrival at the institution to arrival in the operating room (OR) reduced by 4.2 h [4.6 h (IQR 3.9–6.5) to 0.4 h (IQR 0.3–0.6), p < 0.001] and there was improvement in all management steps. The number of referrals direct to otolaryngology increased from 51% to 92%, arrival notification increased from 86% to 100%, avoidance of second x‐ray increased from 63% to 100%, and direct transfer to OR increased from 92% to 100%. Adherence to mitigation strategies such as preoperative administration of honey or sucralfate increased from 0% to 38%, intraoperative use of acetic acid from 3% to 77%, and nasogastric tube insertion from 53% to 92%.
Conclusion
Implementation of ZP substantially reduced the time to BB removal and the use of mitigation strategies in our tertiary care institution. Additional strategies focused on prevention of BB ingestion, and shortening the transfer time to the tertiary care hospital are required to prevent erosive complications. Level of Evidence 3, Case‐series Laryngoscope , 134:5170–5177, 2024
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otolaryngology-Head and Neck Surgery, Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada.
- Division of Pediatric Emergency Medicine, Department of Pediatrics, The Hospital for Sick Children University of Toronto, Toronto, Ontario, Canada.
- Department of Critical Care Medicine, Hospital for Sick Children and University of Toronto, Toronto, Ontario, Canada.
- Department of Anesthesiology and Pain Medicine, Hospital for Sick Children and University of Toronto, Toronto, Ontario, Canada.
- Department of Pediatrics-Division of Neonatology, Hospital for Sick Children and University of Toronto, Toronto, Ontario, Canada.
- Department of Diagnostic Imaging, Hospital for Sick Children and University of Toronto, Toronto, Ontario, Canada.
ORCID-Profile: Samantha Goh, Justine Philteos, Adrian L James, Nikolaus E Wolter
Zitieren
APA
Goh, S., Siu, J. M., Philteos, J., James, A. L., Ostrow, O., McKinnon, N. K., Everett, T., Levine, M., Whyte, H., Lam, C. Z., Propst, E. J., & Wolter, N. E. (2024). Pediatric Esophageal Button Battery Protocol Reduces Time From Presentation to Removal. The Laryngoscope. https://doi.org/10.1002/lary.31607
Vancouver
Goh S, Siu JM, Philteos J, James AL, Ostrow O, McKinnon NK, et al. Pediatric Esophageal Button Battery Protocol Reduces Time From Presentation to Removal. The Laryngoscope. 2024. doi:10.1002/lary.31607