Tissue Sealant Impact on Skull Base Reconstruction Outcomes: A Systematic Review and Meta‐Analysis
The Laryngoscope · 2024
DOI: 10.1002/lary.31390 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift The Laryngoscope, 2024. Verfasst von Jonathan C Pang und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology-Head and Neck Surgery, University of California, Irvine, Orange, California, U.S.A. Hauptthemen laut MEDLINE: Skull Base, Tissue Adhesives, Cerebrospinal Fluid Leak, Plastic Surgery Procedures. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 63 Literaturangaben.
Abstract (Originalsprache)
Objective
Despite significant advances in understanding of skull base reconstruction principles, the role of tissue sealants in modifying postoperative cerebrospinal fluid (CSF) leak outcomes remains controversial. We evaluate postoperative CSF leak incidence associated with tissue sealant use in skull base defect repair during endoscopic skull base surgery (ESBS). Data Sources Web of Science, PubMed/MEDLINE, Scopus, and Cochrane Library. Review Methods Systematic review and meta‐analysis of risk differences (RD). A search strategy identified original studies reporting CSF leakage following ESBS with disaggregation by tissue sealant use and/or type.
Results
27 non‐randomized studies ( n = 2,403) were included for qualitative and meta‐analysis. Reconstruction with a tissue sealant did not significantly reduce postoperative CSF leak risk compared with reconstruction without sealant (RD[95% CI] = 0.02[−0.01, 0.05]). Sub‐analyses of dural sealant (−0.02[−0.11, 0.07]) and fibrin glue (0.00[−0.07, 0.07]) compared with no sealant were similarly unremarkable. Postoperative CSF leakage was not significantly modulated in further sub‐analyses of DuraSeal (0.02[−0.02, 0.05]), Adherus (−0.03[−0.08, 0.03]), or Bioglue (−0.06[−0.23, 0.12]) versus no dural sealant use, or Tisseel/Tissucol versus fibrin glue nonuse (0.00[−0.05, 0.05]). No significant association was seen comparing dural sealant use versus fibrin glue use on pairwise (0.01[−0.03, 0.05]) or network meta‐analysis (−0.01[−0.05, 0.04]). Limitations in source literature prevented sub‐analyses stratified by leak characteristics, defect size and location, and accompanying reconstruction materials.
Conclusion
Tissue sealant use did not appear to impact postoperative CSF leak incidence when compared with nonuse. Higher quality studies are warranted to thoroughly elucidate the clinical value of adjunct sealant use in endoscopic skull base reconstruction. Level of Evidence N/A Laryngoscope , 134:3425–3436, 2024
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Otolaryngology-Head and Neck Surgery, University of California, Irvine, Orange, California, U.S.A.
- Department of Neurological Surgery, University of California, Irvine, Orange, California, U.S.A.
ORCID-Profile: Jonathan C Pang, Arash Abiri, Theodore V Nguyen, Edward C Kuan
Zitieren
APA
Pang, J. C., Bitner, B. F., Nottoli, M. M., Abiri, A., Bui, A. T., Nguyen, C. H., Hsu, T. I., Nguyen, T. V., Hsu, F. P. K., & Kuan, E. C. (2024). Tissue Sealant Impact on Skull Base Reconstruction Outcomes: A Systematic Review and Meta‐Analysis. The Laryngoscope. https://doi.org/10.1002/lary.31390
Vancouver
Pang JC, Bitner BF, Nottoli MM, Abiri A, Bui AT, Nguyen CH, et al. Tissue Sealant Impact on Skull Base Reconstruction Outcomes: A Systematic Review and Meta‐Analysis. The Laryngoscope. 2024. doi:10.1002/lary.31390
BibTeX
@article{Pang2024,
author = {Pang, Jonathan C and Bitner, Benjamin F and Nottoli, Madeline M and Abiri, Arash and Bui, Anh-Tram and Nguyen, Cecilia H and Hsu, Timothy I and Nguyen, Theodore V and Hsu, Frank P K and Kuan, Edward C},
title = {Tissue Sealant Impact on Skull Base Reconstruction Outcomes: A Systematic Review and Meta‐Analysis},
journal = {The Laryngoscope},
year = {2024},
doi = {10.1002/lary.31390}
}