Fachartikel in der Zeitschrift The Laryngoscope, online erschienen am 11.11.2023. Verfasst von Lane B Donaldson und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology-Head and Neck Surgery, Henry Ford Health, Detroit, Michigan, U.S.A. Hauptthemen laut MEDLINE: Surgical Flaps, Turbinates. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 34 Literaturangaben.
Abstract (Originalsprache)
Background
The anterior ethmoidal artery (AEA) flap has been successful in repairing anterior nasal septal perforations and has been presumed to be axially based on AEA branches coursing through or around the cribriform plate (CP). However, limited evidence supports the flap's axial supply. The purposes of this cadaveric and computed tomography (CT) study were to assess the arterial anatomy from the CP to the septum, and to determine AEA flap length to predict ideal flap base width.
Methods
Ten fresh latex‐injected cadavers were utilized for endoscopic dissection to identify arteries traversing the CPs on each side. First, arterial trajectories along the dorsal septum were recorded. Measurements were then made bilaterally along the septum from the middle turbinate (MT) axilla to the nasal branch of the AEA (NBAEA) traversing the CP. Additionally, 100 sinus CTs were reviewed to measure AEA flap lengths bilaterally.
Results
From 10 cadavers, 20 sides were utilized for measurements. In all cadavers, the AEA septal branches coursed diagonally or horizontally along the dorsal septum, and never directly vertically. The mean distance from the MT axilla to the NBAEA was 1.24 ± 1.93 cm (range = 1–1.5 cm). Based on CTs, the mean AEA flap length was 6.40 ± 0.60 cm.
Conclusions
Based on the non‐vertical courses of AEA septal branches, the AEA flap is more likely a random transposition flap than an axial flap. Average AEA flap length ranged from 6.0 to 7.0 cm. Assuming 3:1 length:width ratios, AEA flap base widths should be about 2.0–2.3 cm. Level of Evidence NA Laryngoscope , 134:2100–2104, 2024
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otolaryngology-Head and Neck Surgery, Henry Ford Health, Detroit, Michigan, U.S.A.
ORCID-Profile: Lane B Donaldson, Robert H Deeb, John R Craig
Zitieren
APA
Donaldson, L. B., Deeb, R. H., Momin, S., Eide, J. G., & Craig, J. R. (2024). Cadaveric and Computed Tomography Analysis of the Anterior Ethmoidal Artery Flap. The Laryngoscope, 134(5), 2100-2104. https://doi.org/10.1002/lary.31162
Vancouver
Donaldson LB, Deeb RH, Momin S, Eide JG, Craig JR. Cadaveric and Computed Tomography Analysis of the Anterior Ethmoidal Artery Flap. The Laryngoscope. 2024;134(5):2100-2104. doi:10.1002/lary.31162
BibTeX
@article{Donaldson2024,
author = {Donaldson, Lane B and Deeb, Robert H and Momin, Suhael and Eide, Jacob G and Craig, John R},
title = {Cadaveric and Computed Tomography Analysis of the Anterior Ethmoidal Artery Flap},
journal = {The Laryngoscope},
year = {2024},
volume = {134},
number = {5},
pages = {2100--2104},
doi = {10.1002/lary.31162}
}
EUVIMED