Variables Affecting Cochlear Implant Performance After Loss of Residual Hearing
The Laryngoscope · 2024-04 · 134 (4) · 1868-1873
DOI: 10.1002/lary.31066 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Laryngoscope, online erschienen am 28.09.2023. Verfasst von Nicholas J Thompson und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A. Hauptthemen laut MEDLINE: Cochlear Implants, Speech Perception, Cochlear Implantation. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: MED-EL Corporation.
Abstract (Originalsprache)
Objective
Determine variables that influence post‐activation performance for cochlear implant (CI) recipients who lost low‐frequency acoustic hearing.
Methods
A retrospective review evaluated CNC word recognition for adults with normal to moderately severe low‐frequency hearing (preoperative unaided thresholds of ≤70 dB HL at 250 Hz) who were implanted between 2012 and 2021 at a tertiary academic center, lost functional acoustic hearing, and were fit with a CI‐alone device. Performance scores were queried from the 1, 3, 6, 12, and 24‐month post‐activation visits. A linear mixed model evaluated the effects of age at implantation, array length (long vs. mid/short), and preoperative low‐frequency hearing (normal to mild, moderate, and moderately severe) on speech recognition with a CI alone.
Results
113 patients met the inclusion criteria. There was a significant main effect of interval ( p < 0.001), indicating improved word recognition post‐activation despite loss of residual hearing. There were significant main effects of age ( p = 0.029) and array length ( p = 0.038), with no effect of preoperative low‐frequency hearing ( p = 0.171). There was a significant 2‐way interaction between age and array length ( p = 0.018), indicating that older adults with mid/short arrays performed more poorly than younger adults with long lateral wall arrays when functional acoustic hearing was lost.
Conclusion
CI recipients with preoperative functional low‐frequency hearing experience a significant improvement in speech recognition with a CI alone as compared to preoperative performance—despite the loss of low‐frequency hearing. Age and electrode array length may play a role in post‐activation performance. These data have implications for the preoperative counseling and device selection for hearing preservation candidates. Level of Evidence 4 Laryngoscope , 134:1868–1873, 2024
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A.
- Audiology Department, UNC Health, Chapel Hill, North Carolina, U.S.A.
ORCID-Profile: Nicholas J Thompson, Margaret T Dillon, Kevin D Brown
Förderung
- MED-EL Corporation
Zitieren
APA
Thompson, N. J., Dillon, M. T., Nix, E. P., Overton, A. B., Selleck, A. M., Dedmon, M. M., & Brown, K. D. (2024). Variables Affecting Cochlear Implant Performance After Loss of Residual Hearing. The Laryngoscope, 134(4), 1868-1873. https://doi.org/10.1002/lary.31066
Vancouver
Thompson NJ, Dillon MT, Nix EP, Overton AB, Selleck AM, Dedmon MM, et al. Variables Affecting Cochlear Implant Performance After Loss of Residual Hearing. The Laryngoscope. 2024;134(4):1868-1873. doi:10.1002/lary.31066
BibTeX
@article{Thompson2024,
author = {Thompson, Nicholas J and Dillon, Margaret T and Nix, Evan P and Overton, Andrea B and Selleck, A Morgan and Dedmon, Matthew M and Brown, Kevin D},
title = {Variables Affecting Cochlear Implant Performance After Loss of Residual Hearing},
journal = {The Laryngoscope},
year = {2024},
volume = {134},
number = {4},
pages = {1868--1873},
doi = {10.1002/lary.31066}
}
EUVIMED