EUVIMEDEUVIMED entdecken
Crossref

Development of Automated Tool for Electrode Array Insertion and its Study on Intracochlear Pressure

Aparna Zagabathuni iD, Kishore Kumar Padi, Mohan Kameswaran, Kanagaraj Subramani

The Laryngoscope · 2024

DOI: 10.1002/lary.30966 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Laryngoscope, 2024. Verfasst von Aparna Zagabathuni und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Materials Science and Engineering, National Institute of Technology Calicut, Calicut, India. Hauptthemen laut MEDLINE: Cochlear Implantation, Cochlear Implants, Hearing Loss, Sensorineural. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: Department of Biotechnology, Ministry of Science and Technology, India.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cochlear implantation is the most successful approach for people with profound sensorineural hearing loss. Manual insertion of the electrode array may result in damaging the soft tissue structures and basilar membrane. An automated electrode array insertion device is reported to be less traumatic in cochlear implant surgery.

Objectives

The present work develops a simple, reliable, and compact device for automatically inserting the electrode array during cochlear implantation and test the device to observe intracochlear pressure during simulated electrode insertion.

Methods

The device actuates the electrode array by a roller mechanism. For testing the automated device, a straight cochlea having the dimension of the scala tympani and a model electrode is developed using a 3D printer. A pressure sensor is utilized to observe the pressure change at different insertional conditions.

Results

The electrode is inserted into a prototype cochlea at different speeds without any pause, and it is noticed that the pressure is increased with the depth of insertion of the electrode irrespective of the speed of electrode insertion. The rate of pressure change is observed to be increased exponentially with the speed of insertion.

Conclusion

At an insertion speed of 0.15 mm/s, the peak pressure is observed to be 133 Pa, which can be further evaluated in anatomical models for clinical scenarios. Level of Evidence N/A Laryngoscope , 134:1388–1395, 2024

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cochlear ImplantationCochlear ImplantsHearing Loss, SensorineuralHumansCochleaScala TympaniElectrodes, Implanted

Stichwörter der Autor:innen

automated toolcochleacochlear implantelectrode array

Autor:innen und Institutionen

  • School of Materials Science and Engineering, National Institute of Technology Calicut, Calicut, India.
  • Department of Mechanical Engineering, Indian Institute of Technology Guwahati, Guwahati, India.
  • Madras ENT Research Foundation, Chennai, India.

ORCID-Profile: Aparna Zagabathuni

Förderung

  • Department of Biotechnology, Ministry of Science and Technology, India

Zitieren

APA

Zagabathuni, A., Padi, K. K., Kameswaran, M., & Subramani, K. (2024). Development of Automated Tool for Electrode Array Insertion and its Study on Intracochlear Pressure. The Laryngoscope. https://doi.org/10.1002/lary.30966

Vancouver

Zagabathuni A, Padi KK, Kameswaran M, Subramani K. Development of Automated Tool for Electrode Array Insertion and its Study on Intracochlear Pressure. The Laryngoscope. 2024. doi:10.1002/lary.30966

BibTeX
@article{Zagabathuni2024,
  author = {Zagabathuni, Aparna and Padi, Kishore Kumar and Kameswaran, Mohan and Subramani, Kanagaraj},
  title = {Development of Automated Tool for Electrode Array Insertion and its Study on Intracochlear Pressure},
  journal = {The Laryngoscope},
  year = {2024},
  doi = {10.1002/lary.30966}
}
Kostenlos starten →