Development of Automated Tool for Electrode Array Insertion and its Study on Intracochlear Pressure
The Laryngoscope · 2024
DOI: 10.1002/lary.30966 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Laryngoscope, 2024. Verfasst von Aparna Zagabathuni und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Materials Science and Engineering, National Institute of Technology Calicut, Calicut, India. Hauptthemen laut MEDLINE: Cochlear Implantation, Cochlear Implants, Hearing Loss, Sensorineural. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: Department of Biotechnology, Ministry of Science and Technology, India.
Abstract (Originalsprache)
Cochlear implantation is the most successful approach for people with profound sensorineural hearing loss. Manual insertion of the electrode array may result in damaging the soft tissue structures and basilar membrane. An automated electrode array insertion device is reported to be less traumatic in cochlear implant surgery.
Objectives
The present work develops a simple, reliable, and compact device for automatically inserting the electrode array during cochlear implantation and test the device to observe intracochlear pressure during simulated electrode insertion.
Methods
The device actuates the electrode array by a roller mechanism. For testing the automated device, a straight cochlea having the dimension of the scala tympani and a model electrode is developed using a 3D printer. A pressure sensor is utilized to observe the pressure change at different insertional conditions.
Results
The electrode is inserted into a prototype cochlea at different speeds without any pause, and it is noticed that the pressure is increased with the depth of insertion of the electrode irrespective of the speed of electrode insertion. The rate of pressure change is observed to be increased exponentially with the speed of insertion.
Conclusion
At an insertion speed of 0.15 mm/s, the peak pressure is observed to be 133 Pa, which can be further evaluated in anatomical models for clinical scenarios. Level of Evidence N/A Laryngoscope , 134:1388–1395, 2024
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Materials Science and Engineering, National Institute of Technology Calicut, Calicut, India.
- Department of Mechanical Engineering, Indian Institute of Technology Guwahati, Guwahati, India.
- Madras ENT Research Foundation, Chennai, India.
ORCID-Profile: Aparna Zagabathuni
Förderung
- Department of Biotechnology, Ministry of Science and Technology, India
Zitieren
APA
Zagabathuni, A., Padi, K. K., Kameswaran, M., & Subramani, K. (2024). Development of Automated Tool for Electrode Array Insertion and its Study on Intracochlear Pressure. The Laryngoscope. https://doi.org/10.1002/lary.30966
Vancouver
Zagabathuni A, Padi KK, Kameswaran M, Subramani K. Development of Automated Tool for Electrode Array Insertion and its Study on Intracochlear Pressure. The Laryngoscope. 2024. doi:10.1002/lary.30966
BibTeX
@article{Zagabathuni2024,
author = {Zagabathuni, Aparna and Padi, Kishore Kumar and Kameswaran, Mohan and Subramani, Kanagaraj},
title = {Development of Automated Tool for Electrode Array Insertion and its Study on Intracochlear Pressure},
journal = {The Laryngoscope},
year = {2024},
doi = {10.1002/lary.30966}
}
EUVIMED