EUVIMEDEUVIMED entdecken
Fallbericht

Single‐Port Robotic Removal of a Submucosal Foreign Body in the Distal Hypopharynx

Andrew J Stefan iD, Tamer Ghanem, Ross Mayerhoff iD

The Laryngoscope · 2024

DOI: 10.1002/lary.30882 ↗

Kurz gefasst

Fallbericht in der Zeitschrift The Laryngoscope, 2024. Verfasst von Andrew J Stefan und 2 weiteren Autor:innen. Beteiligte Einrichtung: Wayne State University School of Medicine, Detroit, Michigan, U.S.A. Hauptthemen laut MEDLINE: Robotics, Robotic Surgical Procedures, Laryngoscopes. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 5 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this report, we present a 55‐year‐old female with cervical stenosis that underwent C5‐C7 anterior cervical discectomy and fusion surgery complicated by hardware failure requiring removal. One screw remained after transcervical hardware removal due to operative difficulty with the risk of exposing the hypopharyngeal submucosal space. The retained screw caused the patient significant discomfort and dysphagia prompting a transoral attempt at removal. Using a hypopharynx blade on an oral retractor for access, the single‐port surgical robot successfully removed the foreign body from the distal hypopharynx. In this case, a single‐port surgical robot expanded access to the inferior hypopharynx. Laryngoscope , 134:588–591, 2024

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RoboticsRobotic Surgical ProceduresLaryngoscopesFemaleHumansMiddle AgedHypopharynx

Stichwörter der Autor:innen

foreign bodyhypopharynxsingle-port robotspinal hardwaretransoral robotic surgery

Autor:innen und Institutionen

  • Wayne State University School of Medicine, Detroit, Michigan, U.S.A.
  • Department of Otolaryngology, Henry Ford Health, Detroit, Michigan, U.S.A.

ORCID-Profile: Andrew J Stefan, Ross Mayerhoff

Zitieren

APA

Stefan, A. J., Ghanem, T., & Mayerhoff, R. (2024). Single‐Port Robotic Removal of a Submucosal Foreign Body in the Distal Hypopharynx. The Laryngoscope. https://doi.org/10.1002/lary.30882

Vancouver

Stefan AJ, Ghanem T, Mayerhoff R. Single‐Port Robotic Removal of a Submucosal Foreign Body in the Distal Hypopharynx. The Laryngoscope. 2024. doi:10.1002/lary.30882

BibTeX
@article{Stefan2024,
  author = {Stefan, Andrew J and Ghanem, Tamer and Mayerhoff, Ross},
  title = {Single‐Port Robotic Removal of a Submucosal Foreign Body in the Distal Hypopharynx},
  journal = {The Laryngoscope},
  year = {2024},
  doi = {10.1002/lary.30882}
}