Validation of a 3D‐Printed Percutaneous Injection Laryngoplasty Simulator: A Randomized Controlled Trial
The Laryngoscope · 2024
DOI: 10.1002/lary.30878 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift The Laryngoscope, 2024. Verfasst von Julianna C Kostas und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology-Head and Neck Surgery, Weill Cornell Medicine, Sean Parker Institute for the Voice, New York, New York, U.S.A. Hauptthemen laut MEDLINE: Internship and Residency, Laryngoplasty, Larynx, Otolaryngology. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCATS NIH HHS, NIH HHS, NIA NIH HHS.
Abstract (Originalsprache)
Objective
Simulation may be a valuable tool in training laryngology office procedures on unsedated patients. However, no studies have examined whether existing awake procedure simulators improve trainee performance in laryngology. Our objective was to evaluate the transfer validity of a previously published 3D‐printed laryngeal simulator in improving percutaneous injection laryngoplasty (PIL) competency compared with conventional educational materials with a single‐blinded randomized controlled trial.
Methods
Otolaryngology residents with fewer than 10 PIL procedures in their case logs were recruited. A pretraining survey was administered to participants to evaluate baseline procedure‐specific knowledge and confidence. The participants underwent block randomization by postgraduate year to receive conventional educational materials either with or without additional training with a 3D‐printed laryngeal simulator. Participants performed PIL on an anatomically distinct laryngeal model via trans‐thyrohyoid and trans‐cricothyroid approaches. Endoscopic and external performance recordings were de‐identified and evaluated by two blinded laryngologists using an objective structured assessment of technical skill scale and PIL‐specific checklist.
Results
Twenty residents completed testing. Baseline characteristics demonstrate no significant differences in confidence level or PIL experience between groups. Senior residents receiving simulator training had significantly better respect for tissue during the trans‐thyrohyoid approach compared with control ( p < 0.0005). There were no significant differences in performance for junior residents.
Conclusions
In this first transfer validity study of a simulator for office awake procedure in laryngology, we found that a previously described low‐cost, high‐fidelity 3D‐printed PIL simulator improved performance of PIL amongst senior otolaryngology residents, suggesting this accessible model may be a valuable educational adjunct for advanced trainees to practice PIL. Level of Evidence NA Laryngoscope , 134:318–323, 2024
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otolaryngology-Head and Neck Surgery, Weill Cornell Medicine, Sean Parker Institute for the Voice, New York, New York, U.S.A.
- Department of Otolaryngology-Head and Neck Surgery, Icahn School of Medicine at Mount Sinai, New York, New York, U.S.A.
- Department of Otolaryngology, SUNY Downstate Medical Center, Brooklyn, New York, U.S.A.
- Department of Otolaryngology-Head and Neck Surgery, NYU Langone Health, New York, New York, U.S.A.
ORCID-Profile: Julianna C Kostas, Mark Lee, Diana Kirke, Anaïs Rameau
Förderung
- NCATS NIH HHS
- NIH HHS
- NIA NIH HHS
- ODCDC CDC HHS
- National Institute on Aging
- Common Fund
Zitieren
APA
Kostas, J. C., Lee, A. S., Arunkumar, A., Han, C., Lee, M., Goel, A. N., Alrassi, J., Crosby, T., Clark, C. M., Amin, M., Abu-Ghanem, S., Kirke, D., & Rameau, A. (2024). Validation of a 3D‐Printed Percutaneous Injection Laryngoplasty Simulator: A Randomized Controlled Trial. The Laryngoscope. https://doi.org/10.1002/lary.30878
Vancouver
Kostas JC, Lee AS, Arunkumar A, Han C, Lee M, Goel AN, et al. Validation of a 3D‐Printed Percutaneous Injection Laryngoplasty Simulator: A Randomized Controlled Trial. The Laryngoscope. 2024. doi:10.1002/lary.30878
BibTeX
@article{Kostas2024,
author = {Kostas, Julianna C and Lee, Andrew S and Arunkumar, Amit and Han, Catherine and Lee, Mark and Goel, Alexander N and Alrassi, James and Crosby, Tyler and Clark, Christine M and Amin, Milan and Abu-Ghanem, Sara and Kirke, Diana and Rameau, Anaïs},
title = {Validation of a 3D‐Printed Percutaneous Injection Laryngoplasty Simulator: A Randomized Controlled Trial},
journal = {The Laryngoscope},
year = {2024},
doi = {10.1002/lary.30878}
}
EUVIMED