A Novel Instrument Holder to Improve Operative Efficiency in Endoscopic Laryngeal and Airway Surgery
The Laryngoscope · 2023
DOI: 10.1002/lary.30835 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift The Laryngoscope, 2023. Verfasst von Aseem Jain und 8 weiteren Autor:innen. Beteiligte Einrichtung: College of Medicine, University of Cincinnati, Cincinnati, Ohio, U.S.A. Hauptthemen laut MEDLINE: Larynx, Laryngoscopes. Die Arbeit nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Objective
Receiving instruments from surgical technicians during endoscopic laryngeal and airway microsurgery (ELAM) has challenges including repeated, expeditious handling of delicate instruments and passing them to the surgeon's hand opposite of where the surgical assistant is standing. Optimizing this interaction may reduce surgical errors and improve operative efficiency.
Methods
A proprietary ELAM instrument holder was attached to both sides of the operating room bed. The device consisted of an articulating arm with custom silicone inserts mounted on a tray (storing up to three endoscopic instruments). ELAM cases were randomized to be performed either with (device) or without the holder (control). Using custom software, instrument pass time (IPT), instrument drop rate (IDR), and communication errors (eg handing incorrect instruments) were manually recorded. Qualitative use metrics relating to overall device satisfaction were also obtained.
Results
Data were collected from 25 device and 23 control cases among three different laryngologists. Average IPT was nearly three times quicker for the device (0.80 s, n = 1175 passes) compared with controls (2.09 s, n = 1208 passes) [ p < 0.001]. IPT interquartile range was five times higher for control (1.65 s) versus device cases (0.42 s). IDR was not significantly different [ p = 0.48]; however, device cases had significantly lower communication errors compared to control cases [ p = 0.01]. Surgeons and surgical assistants were similarly satisfied with the device on a 5‐point Likert scale (mean: 4.2/5, standard deviation: 0.92).
Conclusion
The proposed endoscopic instrument holder can improve ELAM operative workflow by reducing instrument passing time and variability without increasing IDR. Level of Evidence 2 Laryngoscope , 133:3492–3498, 2023
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Medicine, University of Cincinnati, Cincinnati, Ohio, U.S.A.
- Department of Communication Sciences and Disorders, University of Cincinnati, Cincinnati, Ohio, U.S.A.
- Division of Laryngology, Department of Otolaryngology-Head and Neck Surgery, University of Cincinnati Medical Center, Cincinnati, Ohio, U.S.A.
ORCID-Profile: Aseem Jain, Sarah M Adams, Rebecca J Howell, Aaron D Friedman
Zitieren
APA
Jain, A., Adams, S. M., Hale, I., Voskoboynik, A., Sissoko, C., Bugada, M., Dion, G. R., Howell, R. J., & Friedman, A. D. (2023). A Novel Instrument Holder to Improve Operative Efficiency in Endoscopic Laryngeal and Airway Surgery. The Laryngoscope. https://doi.org/10.1002/lary.30835
Vancouver
Jain A, Adams SM, Hale I, Voskoboynik A, Sissoko C, Bugada M, et al. A Novel Instrument Holder to Improve Operative Efficiency in Endoscopic Laryngeal and Airway Surgery. The Laryngoscope. 2023. doi:10.1002/lary.30835
BibTeX
@article{Jain2023,
author = {Jain, Aseem and Adams, Sarah M and Hale, Isaac and Voskoboynik, Anna and Sissoko, Cheick and Bugada, Matthew and Dion, Gregory R and Howell, Rebecca J and Friedman, Aaron D},
title = {A Novel Instrument Holder to Improve Operative Efficiency in Endoscopic Laryngeal and Airway Surgery},
journal = {The Laryngoscope},
year = {2023},
doi = {10.1002/lary.30835}
}
EUVIMED