Utilizing a Functional Lumen Imaging Probe for Evaluation of the Pediatric Airway, A Pilot Study
The Laryngoscope · 2024
DOI: 10.1002/lary.30745 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Laryngoscope, 2024. Verfasst von Sarek A Shen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins School of Medicine, Baltimore, Maryland, USA. Hauptthemen laut MEDLINE: Laryngostenosis, Tracheal Stenosis. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIDCD NIH HHS, National Institute on Deafness and Other Communication Disorders.
Abstract (Originalsprache)
Objectives
Accurate and reproducible measurements of the pediatric airway are critical for diagnostic evaluation and management of subglottic and tracheal stenosis. The endoluminal functional lumen imaging probe (EndoFLIP) is a catheter‐based imaging probe which utilizes impedance planimetry to calculate luminal parameters, including cross‐sectional area and compliance. Herein, we demonstrate the feasibility of this system for multidimensional evaluation of the pediatric airway.
Methods
3D‐printed pediatric laryngotracheal models were created based on computed tomography scans, then artificially deformed to simulate both circumferential and posterior subglottic stenosis. Two observers made six measurements of the minimum cross‐sectional area (MCSA) and length of stenosis of each model with EndoFLIP. Agreement between observer measurements and model dimensions was evaluated using Lin's concordance correlation coefficient; inter‐observer reliability was assessed using intraclass correlation.
Results
Four models were created: two without pathology (MCSA: 132.4, 44.3 mm 2 ) and two with subglottic stenosis (MCSA: 28.7, 59.7 mm 2 , stenotic length 27.8, 24.4 mm). Observer measurements of MCSA and length of stenosis demonstrated high concordance with the models ( r = 0.99, 0.95, p < 0.001) with a mean error of 4.5% and 18.2% respectively. There was a low coefficient of variation (0.6%–2.8%) for measurements, indicating high precision. Interrater reliability was high for both MCSA and stenotic length (ICC: 0.99, 0.98).
Conclusions
The EndoFLIP system allows for accurate and reproducible measurements of cross‐sectional area and stenotic length in pediatric airway models. This method may provide further advantages in the evaluation of airway distensibility, as well as measurements of asymmetric airway pathology. Level of Evidence NA Laryngoscope , 134:108–112, 2024
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins School of Medicine, Baltimore, Maryland, USA.
- Department of Pediatrics, Johns Hopkins School of Medicine, Baltimore, Maryland, USA.
ORCID-Profile: Sarek A Shen, Andy S Ding, Kenneth Ng
Förderung
- NIDCD NIH HHS
- National Institute on Deafness and Other Communication Disorders
Zitieren
APA
Shen, S. A., Ding, A. S., Zhao, J., Seo, S., Ng, K., & Walsh, J. (2024). Utilizing a Functional Lumen Imaging Probe for Evaluation of the Pediatric Airway, A Pilot Study. The Laryngoscope. https://doi.org/10.1002/lary.30745
Vancouver
Shen SA, Ding AS, Zhao J, Seo S, Ng K, Walsh J. Utilizing a Functional Lumen Imaging Probe for Evaluation of the Pediatric Airway, A Pilot Study. The Laryngoscope. 2024. doi:10.1002/lary.30745
BibTeX
@article{Shen2024,
author = {Shen, Sarek A and Ding, Andy S and Zhao, Jared and Seo, Stefanie and Ng, Kenneth and Walsh, Jonathan},
title = {Utilizing a Functional Lumen Imaging Probe for Evaluation of the Pediatric Airway, A Pilot Study},
journal = {The Laryngoscope},
year = {2024},
doi = {10.1002/lary.30745}
}
EUVIMED