Metaanalyse in der Zeitschrift The Laryngoscope, online erschienen am 18.07.2022. Verfasst von Zuwei Cao und 6 weiteren Autor:innen. Beteiligte Einrichtung: Center for Rehabilitative Auditory Research, Guizhou Provincial People's Hospital, Guiyang City, China. Hauptthemen laut MEDLINE: Tympanic Membrane, Ear Diseases. Die Arbeit wurde bisher 41-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Department of Health, Great Britain Sasakawa Foundation, National Natural Science Foundation of China.
Abstract (Originalsprache)
Objective
To systematically evaluate the development of Machine Learning (ML) models and compare their diagnostic accuracy for the classification of Middle Ear Disorders (MED) using Tympanic Membrane (TM) images.
Methods
PubMed, EMBASE, CINAHL, and CENTRAL were searched up until November 30, 2021. Studies on the development of ML approaches for diagnosing MED using TM images were selected according to the inclusion criteria. PRISMA guidelines were followed with study design, analysis method, and outcomes extracted. Sensitivity, specificity, and area under the curve (AUC) were used to summarize the performance metrics of the meta‐analysis. Risk of Bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies‐2 tool in combination with the Prediction Model Risk of Bias Assessment Tool.
Results
Sixteen studies were included, encompassing 20254 TM images (7025 normal TM and 13229 MED). The sample size ranged from 45 to 6066 per study. The accuracy of the 25 included ML approaches ranged from 76.00% to 98.26%. Eleven studies (68.8%) were rated as having a low risk of bias, with the reference standard as the major domain of high risk of bias (37.5%). Sensitivity and specificity were 93% (95% CI, 90%–95%) and 85% (95% CI, 82%–88%), respectively. The AUC of total TM images was 94% (95% CI, 91%–96%). The greater AUC was found using otoendoscopic images than otoscopic images.
Conclusions
ML approaches perform robustly in distinguishing between normal ears and MED, however, it is proposed that a standardized TM image acquisition and annotation protocol should be developed. Level of Evidence NA Laryngoscope , 133:732–741, 2023
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Center for Rehabilitative Auditory Research, Guizhou Provincial People's Hospital, Guiyang City, China.
- Centre for Speech and Language Therapy and Hearing Science, Cardiff School of Sport and Health Sciences, Cardiff Metropolitan University, Cardiff, UK.
- Medical Examination Center, Guizhou Provincial People's Hospital, Guiyang City, China.
- Department of Otolaryngology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou City, China.
- Department of Speech-Language Pathology and Audiology, University of Pretoria, Pretoria, South Africa.
Förderung
- Department of Health
- Great Britain Sasakawa Foundation
- National Natural Science Foundation of China
Zitieren
APA
Cao, Z., Chen, F., Grais, E. M., Yue, F., Cai, Y., Swanepoel, W., & Zhao, F. (2023). Machine Learning in Diagnosing Middle Ear Disorders Using Tympanic Membrane Images: A Meta‐Analysis. The Laryngoscope, 133(4), 732-741. https://doi.org/10.1002/lary.30291
Vancouver
Cao Z, Chen F, Grais EM, Yue F, Cai Y, Swanepoel W, et al. Machine Learning in Diagnosing Middle Ear Disorders Using Tympanic Membrane Images: A Meta‐Analysis. The Laryngoscope. 2023;133(4):732-741. doi:10.1002/lary.30291
BibTeX
@article{Cao2023,
author = {Cao, Zuwei and Chen, Feifan and Grais, Emad M and Yue, Fengjuan and Cai, Yuexin and Swanepoel, De Wet and Zhao, Fei},
title = {Machine Learning in Diagnosing Middle Ear Disorders Using Tympanic Membrane Images: A Meta‐Analysis},
journal = {The Laryngoscope},
year = {2023},
volume = {133},
number = {4},
pages = {732--741},
doi = {10.1002/lary.30291}
}
EUVIMED