Reduced patella medialization in valgus and varus knees using a KA‐optimized femoral component in kinematically aligned TKA
Knee Surgery, Sports Traumatology, Arthroscopy · 03.08.2026
DOI: 10.1002/ksa.70563 ↗Kurz gefasst
Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 03.08.2026. Verfasst von Johanna-Maria Simon und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital Munich, LMU Munich, Munich, German…. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Patellofemoral complications after total knee arthroplasty (TKA) are linked to femoral component design and trochlear alignment. This study compared the effects of a kinematically aligned (KA)‐optimized femoral component versus a standard design on patellofemoral kinematics, contact mechanics and quadriceps function, using native knee biomechanics as reference.
Methods
Seventeen fresh‐frozen cadaveric knees (10 valgus, 7 varus) were tested in a dynamic knee rig (30°–130° flexion) under controlled loading, divided into a valgus and a varus group. Patellofemoral kinematics, contact area and peak pressure patterns were recorded in the native state and after KA TKA using either a standard component (prosthetic trochlear angle [PTA] 6°) or a KA‐optimized design (PTA 20°). One‐dimensional statistical parametric mapping (SPM1D) independent two‐sample t tests were applied ( α = 0.05).
Results
The KA‐optimized component reduced medialization between 30° and 70° in both groups (varus: 2.5 mm; valgus 2.0 mm). Patellar tilt remained unchanged. Contact area decreased after TKA without consistent differences between components (valgus: p < 0.001 until 80°; varus: p < 0.001 at 60°–80°). Peak pressure was not reduced with the KA‐optimized design; slightly higher values occurred up to mid‐flexion (+1.1 MPa at 90°), normalizing at higher flexion angles in valgus knees. In varus knees, both designs increased peak pressure at high flexion (+1.5 MPa at 120°). Quadriceps force showed no significant differences.
Conclusion
The KA‐optimized femoral component reduces patellar medialization but does not improve patellofemoral loads or quadriceps efficiency, suggesting that isolated geometric optimization may be insufficient to restore physiological biomechanics after KA TKA. Level of Evidence N/A.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital Munich, LMU Munich, Munich, Germany.
- Division of Anatomy, Center of Anatomy and Cell Biology, Medical University of Vienna, Vienna, Austria.
ORCID-Profile: Johanna-Maria Simon
Zitieren
APA
Simon, J. M., Siedow, T. M., Thorwächter, C., Traxler, H., Kirchhoff, K., Endres, F., Holzapfel, B. M., Müller, P. E., & Niethammer, T. R. (2026). Reduced patella medialization in valgus and varus knees using a KA‐optimized femoral component in kinematically aligned TKA. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.70563
Vancouver
Simon JM, Siedow TM, Thorwächter C, Traxler H, Kirchhoff K, Endres F, et al. Reduced patella medialization in valgus and varus knees using a KA‐optimized femoral component in kinematically aligned TKA. Knee Surgery, Sports Traumatology, Arthroscopy. 2026. doi:10.1002/ksa.70563
BibTeX
@article{Simon2026,
author = {Simon, Johanna-Maria and Siedow, Tara Mauritia and Thorwächter, Christoph and Traxler, Hannes and Kirchhoff, Katharina and Endres, Felix and Holzapfel, Boris Michael and Müller, Peter Ernst and Niethammer, Thomas Richard},
title = {Reduced patella medialization in valgus and varus knees using a KA‐optimized femoral component in kinematically aligned TKA},
journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
year = {2026},
doi = {10.1002/ksa.70563}
}
EUVIMED