EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Femoral component internal rotation in functionally aligned robotic‐assisted total knee arthroplasty does not impair functional outcomes

Andrew Philpott iD, Anton Lambers iD, Serene Lee iD, Dermot Collopy iD, Gavin Clark iD

Knee Surgery, Sports Traumatology, Arthroscopy · 26.06.2026

DOI: 10.1002/ksa.70509 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 26.06.2026. Verfasst von Andrew Philpott und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Austin Hospital, Melbourne, Australia. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Femoral component internal rotation tightens the medial flexion gap and medialises femoral trochlea position, thus influencing patellofemoral tracking and function. Therefore, one of the tenets of mechanically aligned total knee arthroplasty (TKA) has been to avoid femoral component internal rotation relative to the transepicondylar axis (TEA). Our aim was to describe femoral component rotation achieved in functionally aligned TKA and assess the impact of femoral component rotation on functional outcomes.

Methods

A retrospective review of 2760 consecutive, functionally aligned (FA), robotic‐assisted TKAs, undertaken by two senior arthroplasty surgeons was performed. Femoral component rotation was assessed relative to the surgical TEA (sTEA) at the time of implantation using an image‐based TKA system. Primary outcomes were Forgotten Joint Score (FJS) and knee flexion range of motion (ROM) at 1 year follow‐up. Secondary outcomes were knee extension, EuroQol 5‐Dimension Score, Knee Injury and Osteoarthritis Outcome Score for Joint Replacement, Oxford Knee Score and Visual Analogue Scale pain.

Results

Mean femoral component rotation was 0.3° (standard deviation 2.1, range 6.9 internally rotated to 6.5 externally rotated) external to the sTEA. The femoral component was >2° internally rotated to the sTEA in 332 (12%) cases and >4° in 66 (2%) cases. It was rare for the femoral component to be more than 2° internally rotated to the preoperative native posterior condylar axis (0.5%, n = 13). When comparing patients with femoral component internally rotated more than 2° to the sTEA to all other patients, there was no statistically nor clinically relevant difference in any outcome measure at 1 year follow‐up. Multivariate analysis found femoral component rotation to have no significant correlation with postoperative FJS or flexion ROM.

Conclusion

Internally rotating the femoral component relative to the surgical TEA, in a functionally aligned TKA, was not associated with any detrimental impact on clinical outcomes. The ongoing study of alternative alignment strategies that result in relative internal rotation of the femoral component is warranted. Level of Evidence Level III, retrospective comparative study.

Schlagwörter

Stichwörter der Autor:innen

alignmentfemoral rotationfunctional alignmentfunctional outcomesrobotic‐assisted total knee arthroplastytotal knee arthroplasty

Autor:innen und Institutionen

  • Department of Orthopaedics, Austin Hospital, Melbourne, Australia.
  • Medical School, The University of Western Australia, Perth, Western Australia, Australia.
  • Department of Orthopaedics, Northeast Health Wangaratta, Wangaratta, Australia.
  • Perth Hip and Knee Clinic, Perth, Australia.
  • St John of God Subiaco, Murdoch and Midland Hospitals, Perth, Australia.

ORCID-Profile: Andrew Philpott, Anton Lambers, Serene Lee, Dermot Collopy, Gavin Clark

Zitieren

APA

Philpott, A., Lambers, A., Lee, S., Collopy, D., & Clark, G. (2026). Femoral component internal rotation in functionally aligned robotic‐assisted total knee arthroplasty does not impair functional outcomes. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.70509

Vancouver

Philpott A, Lambers A, Lee S, Collopy D, Clark G. Femoral component internal rotation in functionally aligned robotic‐assisted total knee arthroplasty does not impair functional outcomes. Knee Surgery, Sports Traumatology, Arthroscopy. 2026. doi:10.1002/ksa.70509

BibTeX
@article{Philpott2026,
  author = {Philpott, Andrew and Lambers, Anton and Lee, Serene and Collopy, Dermot and Clark, Gavin},
  title = {Femoral component internal rotation in functionally aligned robotic‐assisted total knee arthroplasty does not impair functional outcomes},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2026},
  doi = {10.1002/ksa.70509}
}
Kostenlos starten →